An interventional study of EEG-Based Brain-Computer Interface Device in Healthy Volunteers - Male and Female, sponsored by Universidade Federal do Paraná. Not yet recruiting at 2 sites in Brazil. Open to participants aged 18 Years and older, including healthy volunteers. Per ClinicalTrials.gov, last updated 2026-11-06.
Sponsored by Universidade Federal do Paraná · Not applicable, Interventional, and Basic science
This study evaluates the mental workload and user experience associated with a Brain-Computer Interface (BCI) device called Exobots. The Exobots system uses a non-invasive electroencephalography (EEG) headset to detect neural signals and control a robotic glove that assists hand movement. The primary goal is to assess how three different system sensitivity levels (low, medium, high) impact mental effort, usability, and overall user perception. Healthy adult volunteers (students and staff from IFPR and UFPR) will participate in a single experimental session. During the session, they will perform a repeated mental imagery task (imagine hand movement) while the EEG records their brain activity. After each sensitivity block, participants will complete standardized questionnaires (NASA Task Load Index and User Experience Questionnaire) and a semi-structured qualitative interview about their experience. By combining objective neurophysiological data with subjective feedback, this research aims to identify optimal sensitivity thresholds that minimize cognitive strain and maximize user comfort. The findings are expected to provide technical recommendations for designing more adaptive, user-centered BCI systems for future neurorehabilitation applications.
Background and Rationale
Brain-Computer Interfaces (BCIs) are increasingly employed in neurorehabilitation settings to assist individuals with motor impairments. While these systems enable direct neural control of assistive devices, there is a significant gap in understanding the cognitive demands they impose on users. Excessive mental workload can lead to frustration, disengagement, and suboptimal therapeutic outcomes. This study addresses this gap by applying a neuroergonomic approach-integrating objective neurophysiological measures with subjective user experience (UX) assessments.
Objectives
Primary Objective: To evaluate cognitive load during interaction with the Exobots BCI device by integrating neurophysiological metrics (EEG), psychometric UX scores, and subjective user perceptions.
Secondary Objectives:
Study Design
This is an interventional, single-group, experimental study without a control arm. All participants will undergo the same protocol, testing three distinct sensitivity levels (low, medium, high) in a within-subjects design, with the order of sensitivity levels counterbalanced to avoid order effects.
Study Population and Sample Size
Healthy adults (aged 18 years or older) who are students (undergraduate, graduate, technical level) or staff members from the Federal University of Paraná (UFPR) and the Federal Institute of Paraná (IFPR) will be recruited.
The minimum sample size was calculated using G*Power software (version 3.1.9.7) for a bivariate normal correlation model (Exact test, Family: Correlation). Considering an expected effect size of r = 0.50, a significance level of α = 0.05, and a statistical power of (1-β) = 0.80, the calculation indicated a minimum of 29 participants. To ensure statistical robustness and account for potential data loss due to EEG artifacts or voluntary dropouts, the target enrollment is set at 30 participants, with recruitment extended to up to 60 individuals if necessary.
Intervention and Procedures
Screening and Consent: Interested individuals will receive and sign the Informed Consent Form (TCLE). A screening questionnaire will be administered to verify inclusion/exclusion criteria (e.g., no neurological disorders, no recent head injuries).
Device and Preparation: Participants will interact with the Exobots device (provided by Neurobots). An elastic cap equipped with six dry/wet EEG electrodes will be placed on the participant's scalp. A water-based conductive gel will be applied to the contact points to ensure optimal signal quality. The robotic glove will be fitted to the participant's hand.
Calibration: The system will be calibrated to recognize each participant's specific neural patterns. Based on the calibration, three distinct sensitivity thresholds (low, medium, high) will be defined and tested individually.
Experimental Protocol: Each participant will complete a sequence of repeated cycles consisting of four sequential steps:
Prepare: The participant focuses attention on their hand in anticipation of the command.
Think: The participant imagines opening/closing their hand without physically executing the movement. The EEG system detects the motor imagery signal. If the signal is maintained above the predetermined threshold for three consecutive seconds, the robotic glove is activated.
Move: The robotic glove passively moves the participant's hand. The participant is instructed to voluntarily accompany this movement if possible.
Relax: The participant stops focusing and rests for a few seconds before the next cycle.
Each sensitivity level will be tested in blocks of approximately 10 minutes, totaling approximately 35 minutes of effective interaction per participant. Sessions will be scheduled in advance, with at least 48 hours' notice.
Outcome Measures
Neurophysiological: Continuous 6-channel EEG recording throughout the task. Spectral power analysis will focus on theta (4-8 Hz), alpha (8-12 Hz), and beta (12-30 Hz) bands, with particular emphasis on the theta/beta ratio as a validated marker of cognitive load.
Psychometric: Immediately after each sensitivity block, participants will complete the NASA Task Load Index (NASA-TLX) to assess perceived mental, physical, and temporal demands, effort, and frustration. At the end of the entire session, the User Experience Questionnaire (UEQ) will be administered to evaluate pragmatic and hedonic quality attributes.
Qualitative: A semi-structured interview with open-ended questions and thematic cards will be conducted to capture nuanced perceptions regarding the physical interface, comfort, and overall experience that standardized scales may not fully address.
Statistical Analysis
Pearson correlation coefficients will be calculated to assess the association between neurophysiological metrics (e.g., theta/beta ratio, alpha power) and UX scores (UEQ and NASA-TLX). A significance level of p \< 0.05 will be adopted. Qualitative data will be analyzed using content analysis techniques to identify recurring themes and insights.
Ethical Considerations
The study protocol was reviewed and approved by the Research Ethics Committee of the Federal Technological University of Paraná (CEP/UTFPR) under Approval Number 8.558.948 (issued July 2, 2026; CAAE: 97426026.1.0000.0165). All procedures comply with Brazilian regulations (Resolution CNS 466/12 and LGPD - Lei Geral de Proteção de Dados).
Participants will be informed that no direct clinical benefits are expected, but that their participation will contribute to the scientific advancement of assistive technologies. Risks are minimal and include mild scalp discomfort from the EEG cap/gel, transient fatigue, or mild frustration. Participants may take breaks or withdraw at any time without penalty. All data will be anonymized, stored on a password-protected local hard drive, and kept confidential.
Data Monitoring Committee
A formal Data Monitoring Committee (DMC) will not be established, as this is a low-risk, non-clinical, academic study with healthy volunteers and no investigational drug or device under IDE regulations.
Universidade Federal do Paraná is the lead sponsor of 15 studies on the registry; 4 are open to participants now.
Counted across the registry records on this site, refreshed daily.
Go through the criteria one by one — yes, no or not sure — and take the list to your doctor or the study team. Kept in this browser only.
Exclusion Criteria:
Participants perform motor imagery tasks (imagining hand movements) while using the Exobots EEG-based BCI device. The system detects neural signals and activates a robotic glove to assist hand movement. Three distinct sensitivity thresholds (low, medium, high) are tested in a counterbalanced order within a single 35-minute experimental session.
Other: EEG-Based Brain-Computer Interface Device
Non-invasive electroencephalography (EEG)-based Brain-Computer Interface (BCI) system consisting of a 6-channel EEG headset and a robotic hand exoskeleton (glove). The device detects motor imagery neural signals associated with imagined hand movements. When the EEG signal is maintained above a predefined sensitivity threshold for three consecutive seconds, the system triggers the robotic glove to passively move the participant's hand. The study evaluates three distinct sensitivity levels (low, medium, high) during individual calibration. The EEG headset uses water-based conductive gel on contact points to ensure signal quality. The device is manufactured by Neurobots and provided for this research.
Also known as: Exobots BCI System
EEG Theta/Beta Ratio as a Neurophysiological Marker of Cognitive Load
Change in the theta/beta spectral power ratio derived from 6-channel electroencephalography (EEG) recordings during motor imagery (imagined hand movement) tasks. The theta/beta ratio is a validated neurophysiological indicator of cognitive workload and mental effort. This measure is compared across the three distinct device sensitivity levels (low, medium, high) to assess differences in cognitive demand.
Time frame: Measured continuously during each 10-minute experimental block (blocks 1, 2, and 3) throughout the single 35-minute session.
NASA Task Load Index (NASA-TLX) Global Workload Score
Subjective assessment of perceived mental workload using the NASA-TLX questionnaire. The instrument evaluates six dimensions: mental demand, physical demand, temporal demand, performance, effort, and frustration. The global workload score ranges from 0 to 100, with higher scores indicating greater perceived workload.
Time frame: Immediately after each sensitivity block (3 times total) during the experimental session.
User Experience Questionnaire (UEQ) Scores
Assessment of user experience using the standardized User Experience Questionnaire (UEQ). The instrument measures six scales: Attractiveness, Perspicuity, Efficiency, Dependability, Stimulation, and Novelty. Each scale ranges from -3 (very negative) to +3 (very positive), with higher scores indicating a more favorable user experience.
Time frame: At the end of the entire experimental session.
Qualitative Feedback on BCI Physical Interface and Overall Experience
Thematic content analysis of responses collected through a semi-structured qualitative interview consisting of open-ended questions and visual thematic cards. The analysis captures nuanced perceptions regarding the physical interface (EEG cap and robotic glove), comfort, emotional engagement, usability, and suggestions for device improvement.
Time frame: Immediately following the conclusion of the experimental session.
Individual Operational Sensitivity Thresholds
Identification of the optimal sensitivity level (low, medium, or high) for each participant based on the calibration phase and successful device triggering during motor imagery tasks. This measure assesses how individual neural signal characteristics influence the optimal threshold for reliable BCI operation.
Time frame: During the calibration phase and across all three experimental blocks within the session.
Plan to share: No — Ethical or Consent Restrictions: Participants may not have given explicit consent for their data to be shared beyond the original study.Legal or Institutional Policies: Data sharing may be restricted by Brazillian laws.
From the registry record's own update history. This site started tracking changes on Sep 25, 2026; for anything earlier, see the record history on ClinicalTrials.gov ↗
This study is not yet recruiting, as verified in Nov 2026. You cannot join it, but the record below documents what was studied.
Get an email when the registry record changes — status, dates, results — or when someone posts here.
Sign in to followQuestions and observations about this study, from anyone following it. Not medical advice, and not a channel to the study team — their contact details are on the registry record.
Sign in to join the discussion. Reading takes no account; posting does. You choose a display name, and a pseudonym is the default.
Nothing here yet. If you are running this trial, taking part in it, or weighing whether to, this is the place to say so.
Universidade Federal do Paraná