An interventional study of Freehand Immediate Implant Placement and Tooth-Supported Static Computer-Guided Implant Placement in Edentulism in Lower Jaw, sponsored by Menoufia University. Recruiting at 1 site in Egypt. Open to participants aged 20 Years to 60 Years, including healthy volunteers. Per ClinicalTrials.gov, last updated 2026-10-13.
Sponsored by Menoufia University · Not applicable, Interventional, and Treatment
Help build ClinicalTrials.gg — short surveys, remote interviews or testing, in your language. Take part →
This randomized clinical study will compare the accuracy of immediate implant placement performed using three different surgical approaches: freehand surgery, conventional tooth-supported static computer-guided surgery, and a tooth- and socket-supported static surgical guide.
Patients requiring extraction of a mandibular first or second molar, or a retained root in the same region, followed by immediate implant placement will be enrolled. All participants will undergo three-dimensional preoperative treatment planning using cone-beam computed tomography and intraoral scanning. Participants will then be randomly allocated to one of three groups according to the assigned surgical technique.
The primary outcome will be the three-dimensional accuracy of implant placement, determined by comparing the virtually planned implant position with the clinically achieved implant position. Coronal, apical, angular, and depth deviations will be evaluated using postoperative three-dimensional imaging.
The study will determine whether the use of conventional tooth-supported or tooth- and socket-supported static surgical guides results in different implant positioning accuracy compared with freehand immediate implant placement.
Immediate implant placement can reduce treatment time and the number of surgical interventions; however, accurate three-dimensional implant positioning can be challenging because the anatomy of the extraction socket does not necessarily correspond to the ideal prosthetically driven implant position. Static computer-guided implant surgery allows the virtually planned implant position to be transferred to the surgical field, but its accuracy may be influenced by the design and stability of the surgical guide.
This randomized clinical study will compare the accuracy of immediate implant placement using three surgical approaches: freehand surgery, conventional tooth-supported static computer-guided surgery, and a tooth- and socket-supported static surgical guide.
Patients aged 20-56 years requiring extraction of a mandibular first or second molar, or a retained root in the same region, followed by immediate implant placement will be considered for enrollment. Eligible participants will be classified as American Society of Anesthesiologists Physical Status I or II, have satisfactory oral hygiene, and be able to comply with the scheduled follow-up protocol. Only Class I extraction sockets planned for rehabilitation with a single-unit screw-retained implant-supported crown will be included.
Participants will undergo standardized preoperative digital assessment, including cone-beam computed tomography and intraoral scanning. The ideal implant position, angulation, depth, and dimensions will be virtually planned according to the available anatomy and intended prosthetic restoration. Participants will then be randomly allocated to one of three groups.
Group 1 will receive immediate implant placement using a freehand surgical approach without a surgical guide. Group 2 will receive immediate implant placement using a conventional tooth-supported static surgical guide fabricated according to the virtual implant plan. Group 3 will receive immediate implant placement using a tooth- and socket-supported static surgical guide designed to obtain stabilization from both the remaining dentition and the extraction socket.
All surgical procedures will be performed by a single experienced clinician under local anesthesia. Atraumatic extraction will be performed with preservation of the extraction socket walls, particularly the buccal cortical plate, and routine flap elevation will be avoided. The implants will be placed according to the allocated surgical protocol and the manufacturer's recommended surgical procedure. Insertion torque and implant stability quotient will be recorded immediately after implant placement.
The primary outcome will be three-dimensional implant placement accuracy. Following implant placement, postoperative cone-beam computed tomography will be obtained and registered with the corresponding preoperative virtual treatment plan. The clinically achieved implant position will be compared with the planned position.
Accuracy will be assessed using coronal deviation, defined as the three-dimensional linear distance between the planned and actual implant positions at the implant platform; apical deviation, defined as the three-dimensional linear distance between the planned and actual implant positions at the implant apex; angular deviation, defined as the three-dimensional angular difference between the longitudinal axes of the planned and clinically placed implants; and depth deviation, defined as the difference in the apicocoronal position between the planned and clinically achieved implant positions.
The study will test the null hypothesis that there are no significant differences in implant positioning accuracy among immediate implant placement performed using freehand surgery, conventional tooth-supported static surgical guides, and tooth- and socket-supported static surgical guides.
Menoufia University is the lead sponsor of 202 studies on the registry; 55 are open to participants now.
Counted across the registry records on this site, refreshed daily.
Go through the criteria one by one — yes, no or not sure — and take the list to your doctor or the study team. Kept in this browser only.
Exclusion Criteria
Underlined terms in the criteria open these too. Explained by clinicaltrials.gg, not part of the registry record. The study team decides who can take part.
The anaesthetists’ scale of health before surgery: I is healthy, II has a mild illness that is under control, III a severe one, IV a severe illness that is a constant threat to life. V and VI are used for the critically ill and for organ donors.
ASA physical status
The anaesthetists’ scale of health before surgery: I is healthy, II has a mild illness that is under control, III a severe one, IV a severe illness that is a constant threat to life. V and VI are used for the critically ill and for organ donors.
Explained by clinicaltrials.gg, not part of the registry record. The study team decides who can take part.
Participants assigned to this arm will undergo immediate implant placement using a freehand surgical approach without a surgical guide. The virtually planned implant position will be available as a reference, but no surgical guide will be used during osteotomy preparation or implant insertion.
Procedure: Freehand Immediate Implant Placement
Participants assigned to this arm will undergo immediate implant placement using a conventional tooth-supported static surgical guide fabricated according to the finalized virtual implant plan. The guide will be seated and its stability verified before guided osteotomy preparation and implant placement.
Procedure: Tooth-Supported Static Computer-Guided Implant Placement
Participants assigned to this arm will undergo immediate implant placement using a tooth- and socket-supported static surgical guide designed to obtain stabilization from both the remaining dentition and the extraction socket. Proper seating and stability will be confirmed before guided osteotomy preparation and implant placement.
Procedure: Tooth- and Socket-Supported Static Guided Implant Placement
Immediate implant placement performed using a freehand surgical approach without a surgical guide.
Immediate implant placement performed using a conventional tooth-supported static surgical guide fabricated according to the virtual implant plan.
Immediate implant placement performed using a tooth- and socket-supported static surgical guide designed to obtain stabilization from both the remaining dentition and the extraction socket.
Three-dimensional implant placement accuracy
Three-dimensional implant placement accuracy will be assessed by comparing the clinically achieved implant position with the preoperatively planned virtual implant position using postoperative cone-beam computed tomography (CBCT) and three-dimensional registration. Accuracy will be evaluated by measuring coronal deviation, apical deviation, angular deviation, and depth deviation between the planned and clinically achieved implant positions.
Time frame: Immediately after implant placement
Plan to share: No — Up on reasonable request.
No publications or documents are linked to this record.
Started Apr 2026 (actual). Primary completion is estimated for Apr 2027, 12 months after the start.
How these figures are worked out, and which studies are left out of them.
From the registry record's own update history. This site started tracking changes on Sep 25, 2026; for anything earlier, see the record history on ClinicalTrials.gov ↗
Eligibility is decided by the study team. Share this record with your doctor or contact the team directly.
Contact study teamGet an email when the registry record changes — status, dates, results — or when someone posts here.
Sign in to followQuestions and observations about this study, from anyone following it. Not medical advice, and not a channel to the study team — their contact details are on the registry record.
Sign in to join the discussion. Reading takes no account; posting does. You choose a display name, and a pseudonym is the default.
Nothing here yet. If you are running this trial, taking part in it, or weighing whether to, this is the place to say so.