An interventional study of Training in Teaching Manual Neonatal Ventilation, sponsored by Scuola Superiore di Studi Universitari e di Perfezionamento Sant'Anna. Completed at 1 site in Tanzania. Per ClinicalTrials.gov, last updated 2026-06-24.
Sponsored by Scuola Superiore di Studi Universitari e di Perfezionamento Sant'Anna · Not applicable, Interventional, and Health services research
The goal of this clinical trial is to build capacity and assess the teaching effectiveness of a new simulator for manual neonatal ventilation in third-year nursing and clinical officer students, as well as healthcare professionals from the neonatology, gynecology, and pediatric departments.
The main questions it aims to answer are:
Participants will:
Background and Rationale
Neonatal mortality in sub-Saharan Africa remains disproportionately high-26 deaths per 1,000 live births in 2023, which is 8.7 times higher than rates in Europe and North America. A significant portion of these deaths are attributable to preventable and treatable conditions occurring during birth. While skilled birth attendance can prevent up to 40% of neonatal deaths, assistance rates in sub-Saharan Africa are drastically low (40%) compared to high-income countries (90%). Consequently, strengthening the capacity of the health workforce to deliver essential newborn care is a critical priority.
Neonatal resuscitation is a complex, time-sensitive procedure. Due to severe limitations in access to advanced respiratory technologies in these regions, manual ventilation using a self-inflating bag and face mask constitutes the primary method of respiratory support. Because manual ventilation is highly operator-dependent and can cause substantial harm if performed incorrectly, technical proficiency is paramount. Simulation-based training is internationally recommended to improve provider competence, yet data on the real-world implementation, acceptability, and educational effectiveness of low-cost, high-fidelity simulators tailored to low-resource settings remains limited. This study evaluates a newly designed simulator developed specifically for the Tanzanian environment to ensure healthcare workers can acquire and maintain resuscitation skills.
Study Objectives
The specific objectives of this study are:
to examine user-reported usability and perceived usefulness of the simulator configurations.
Investigational Device Details
The novel, low-cost, high-fidelity neonatal simulator is designed to replicate neonatal airway anatomy and ventilation mechanics while providing objective performance feedback.
Anatomical Construction: The simulator integrates a physical manikin with internal anatomy designed to mimic the upper airways, lungs, and stomach.
Physiological Mechanics: The device mimics physiological movements, specifically the visible rise of the chest and abdomen during successful ventilation. It also features a mechanical obstruction of the esophagus if the head is not correctly placed in the required "sniffing" position.
Sensory and Digital Interface: The system incorporates pressure sensors and connects to a mobile user interface (app) that enables real-time data acquisition. The app provides the operator with real-time visual and auditory feedback regarding ventilation rate and pressure.
Study Design and Allocation
This is a prospective, randomized, and controlled study conducted at the Tosamaganga Regional Referral Hospital (TRRH) and the Tosamaganga Institute of Health and Allied Sciences (TIHAS) in the Iringa region of Tanzania.
The study population consists of two cohorts: second-year undergraduate clinical officer students at TIHAS (with no prior manual ventilation experience) and local health professionals (nursing, midwifery, and neonatal care) working at TRRH. A total of 42 students and 37 health professionals were enrolled.
Participants within each cohort were randomly assigned to one of three groups to evaluate the teaching effectiveness of different simulator configurations:
Study Protocol and Workflow
The training course was delivered over four consecutive days (June 17-20, 2025).
Data Collection and Statistical Analysis Plan
All data were anonymized using unique numeric identifiers to link datasets across sessions. Data triangulation was achieved through three primary streams: automated simulator data, expert tutor evaluations, and self-reported surveys.
- Primary Outcome Analysis (Educational Effectiveness): The primary outcome was ventilatory performance measured by the simulator during the six training trials, specifically the mean and standard deviation (Coefficient of Variation) of the ventilation rate (target: 40 BPM) and peak inspiratory pressure (target: 25 cmH2O). Longitudinal evolution across the trials was analyzed using linear mixed-effects models, evaluating trial number, group assignment, and their interaction.
- Secondary Outcome Analysis (Knowledge and Skill acquisition/Reinforcement): Assessed via data from the final Day 4 evaluation session. Outcomes included simulator data, structured tutor performance scores (0 = poor, 0.5 = average, 1 = good), and theoretical knowledge scores (pre/post-training questionnaire). Continuous variables were analyzed using ANOVA (ANalysis Of VAriance) a (following Shapiro-Wilk testing for normality), and paired theoretical knowledge was analyzed using the Wilcoxon test.
- Tertiary Outcome Analysis (Simulator Acceptability): User-reported acceptability was measured across four Technology Acceptance Model (TAM) dimensions: Perceived Usefulness (PU), Perceived Ease-of-Use (PEU), Behavioral Intention (BI), and Fidelity of the Simulator (FS), rated on a 7-point Likert scale. Associations between these latent variables and proposed cause-effect hypotheses were tested using a partial least squares structural equation model.
Scuola Superiore di Studi Universitari e di Perfezionamento Sant'Anna is the lead sponsor of 5 studies on the registry; 3 are open to participants now.
Counted across the registry records on this site, refreshed daily.
Exclusion Criteria:
Group A used a medium-fidelity passive setup of the simulator without mechanical feedback or mobile user interface guidance.
Other: Training
Group B used a high-fidelity passive setup of the simulator providing mechanical feedback through chest and/or abdominal rise, without mobile user interface guidance.
Other: Training
Group C used a high-fidelity active setup of the simulator combining mechanical feedback with real-time sensor-based guidance via a mobile user interface.
Other: Training
Medical training on manual neonatal ventilation with phisical simulator
Peak Inspiratory Pressure (PIP) (Objective 1)
The primary outcome, used to assess the Objective 1, was the ventilatory performance measured by the simulator, i.e. Peak Inspiratory Pressure (PIP) during hands-on training on Day 2 and Day 3, and the evaluation session on Day 4. In accordance with international guidelines, we considered as gold-standard a PIP of 25 cmH₂O (centimeters of water). For each participant and trial, we computed the mean and standard deviation of PIP.
Time frame: Day 2, Day 3 and Day 4
Ventilation Rate (Objective 1)
The other primary outcome, used to assess the Objective 1, was the ventilatory performance measured by the simulator, i.e. Ventilation Rate during hands-on training on Day 2 and Day 3, and the evaluation session on Day 4. In accordance with international guidelines, we considered as gold-standard a Ventilation Rate of 40 breaths per minute. For each participant and trial, we computed the mean and standard deviation of the Ventilation Rate .
Time frame: Day 2, Day 3 and Day 4
Skill acquisition assessment (Objectives 2 and 3)
The secondary outcomes, used to evaluate Objectives 2 and 3, were acquisition and reinforcement of manual ventilation knowledge and skills, assessed through: (1) data from the simulator sensors acquired during the final evaluation session, (2) objective tutor-based performance evaluation using a structured quantitative scoring sheet on a three-point scale (0 = poor, 0.5 = average, 1 = good, eTable 16 in Supplement 1), (3) theoretical knowledge assessment (pre and post-training true/false questionnaire).
Time frame: Day 1 and day 4
User-reported usability and perceived usefulness (Objective 4)
The tertiary outcome used to evaluate Objective 4, were user-reported measures of simulator acceptability over the four dimensions of the TAM scale (Technology Acceptance Model): Perceived Usefulness (PU), Perceived Ease-of-Use (PEU), Behavioural Intention (BI), and Fidelity of the Simulator (FS). The items were tailored to the characteristics of the simulator and rated on 7 points Likert scales. A final aggregated score was obtained.
Time frame: Day 4
Plan to share: Yes — Anonimized and aggregated data corresponding to the primary outcomes (mean and standard deviations of PIP and Ventilation Rate per trial per group).
This study is completed, as verified in Jun 2026. You cannot join it, but the record below documents what was studied.
Get an email when the registry record changes — status, dates, results — or when someone posts here.
Sign in to followQuestions and observations about this study, from anyone following it. Not medical advice, and not a channel to the study team — their contact details are on the registry record.
Sign in to join the discussion. Reading takes no account; posting does. You choose a display name, and a pseudonym is the default.
Nothing here yet. If you are running this trial, taking part in it, or weighing whether to, this is the place to say so.
Scuola Superiore di Studi Universitari e di Perfezionamento Sant'Anna