An interventional study of Ultrasound-Derived Fractional Flow Reserve Computational System in Percutaneous Coronary Intervention, Intravenous Ultrasound and Coronary Physiology, sponsored by China National Center for Cardiovascular Diseases. Recruiting at 1 site in China. Open to participants aged 18 Years and older. Per ClinicalTrials.gov, last updated 2026-03-03.
Sponsored by China National Center for Cardiovascular Diseases · Not applicable, Interventional, and Treatment
IVUS-FFR Online Accuracy for Coronary Stenosis What is this study testing? This study is testing a new technology called IVUS-FFR , which uses ultrasound imaging inside heart arteries (IVUS) to quickly measure whether a narrowed artery ( coronary stenosis ) is reducing blood flow. Unlike the current standard test (FFR), this new method doesn't require extra wires or medication to work.
Why is this important?
Many patients with heart artery narrowing need tests to decide if a stent is necessary.
Current FFR tests involve inserting a pressure wire and giving medication (like adenosine) that can cause discomfort.
IVUS-FFR could provide equally accurate results faster, cheaper, and more comfortably .
What happens in the study?
If you join:
Standard heart artery imaging (angiogram) will be performed. An ultrasound probe (IVUS) will be moved through the artery to create detailed images.
The new IVUS-FFR software will analyze these images immediately to estimate blood flow.
For comparison, a standard FFR test (with pressure wire and medication) will also be done.
All steps use existing approved devices and take \<10 extra minutes. Who can participate?
Adults (≥18 years) with:
Suspected or known heart artery disease At least one artery narrowing (30%-90% blocked) Excluded: Recent heart attack (\<72 hrs), severe kidney/heart failure, or pregnancy.
What are the risks and benefits?
Risks: Same as routine heart catheterization (bleeding, infection, artery injury). The IVUS and FFR steps add minimal extra risk.
Benefits: No direct benefit, but results may improve future care by reducing need for invasive tests.
Study goal:
To validate if IVUS-FFR is as accurate as the current FFR standard in 292 patients across multiple hospitals in China.
Who is running the study? Led by heart specialists at Fuwai Hospital (Beijing) - China's top cardiovascular center - with ethics committee oversight.
China National Center for Cardiovascular Diseases is the lead sponsor of 256 studies on the registry; 134 are open to participants now.
Counted across the registry records on this site, refreshed daily.
Inclusion Criteria General Requirements
Intervention Protocol Participants receive a real-time functional coronary evaluation using the integrated IVUS-FFR system during diagnostic angiography. The procedure consists of three sequential phases: IVUS Image Acquisition A clinically approved IVUS catheter (40MHz frequency) is advanced to the target coronary segment Standardized automated pullback (0.5 mm/sec) captures cross-sectional vessel images Minimum imaging length: 30mm proximal-to-distal to stenosis Real-Time Computational Analysis DICOM data transfer to IVUS-FFR processing platform AI-driven segmentation of: Lumen boundaries External elastic lamina (EEL) Plaque morphology Hemodynamic simulation using: Adaptive blood flow models based on Murray's law Branching-specific flow distribution algorithms Processing time: ≤90 seconds Diagnostic Output Delivery Primary metric: Computed IVUS-FFR value (scale 0-1) Clinical threshold: IVUS-FFR ≤0.80 = hemodynamically significant stenosis Quality control: Auto
Diagnostic Test: Ultrasound-Derived Fractional Flow Reserve Computational System
1. Core Technological Innovation This diagnostic system revolutionizes coronary stenosis assessment by integrating intravascular ultrasound (IVUS) imaging with real-time computational physiology . Its proprietary technology features: AI-driven vessel segmentation : Deep neural networks automatically delineate lumen boundaries and external elastic lamina from IVUS images, enabling millimeter-level precision in 3D coronary reconstruction. Dynamic hemodynamic modeling : Adaptive algorithms apply Murray's law to calculate branch-specific blood flow distribution, accounting for plaque composition (calcified/fibrous/lipidic) and vessel tapering. 2. Procedural Implementation The intervention seamlessly integrates into standard coronary angiography workflows: Image acquisition : A 40MHz IVUS catheter performs automated pullback (0.5 mm/sec) across the target stenosis and adjacent segments. Real-time processing : DICOM data transfers to an embedded GPU server, initiat
Diagnostic Accuracy of IVUS-FFR in Identifying Hemodynamically Significant Coronary Stenosis
Diagnostic accuracy of IVUS-FFR (online, HRU100) vs. invasive FFR (pressure wire, adenosine) for functionally significant stenosis (≤0.80). Primary metric: proportion of correct classifications (true positives + true negatives) among all lesions. Secondary metrics: sensitivity, specificity, PPV, NPV, AUC. Measurement: paired real-time assessment; IVUS-FFR computed during catheterization, then FFR measured. Blinding: IVUS-FFR operator blinded to FFR result until after recording. Quality assurance: core lab verification; analyses with segmentation confidence \<95% rejected.
Time frame: Single time point assessment: immediately after IVUS-FFR computation during the index cardiac catheterization procedure.
Diagnostic Accuracy of IVUS-FFR in Identifying Hemodynamically Significant Coronary Stenosis
This outcome measures the diagnostic performance of IVUS-FFR (computed online during catheterization using the HRU100 system) against the gold standard invasive FFR (measured with a pressure wire under adenosine-induced hyperemia). Functionally significant stenosis is defined as ≤0.80 for both methods. The primary metric is the proportion of correct classifications (true positives + true negatives) among all evaluated lesions. Secondary metrics derived from the same data include sensitivity, specificity, positive predictive value, negative predictive value, and area under the ROC curve. Measurement Method: Paired real-time assessment: IVUS-FFR computed first, immediately followed by invasive FFR measurement. Blinding: IVUS-FFR operator masked to FFR result until after recording. Quality Assurance: Core laboratory verification of all measurements; automatic rejection of analyses with segmentation confidence \<95%.
Time frame: Single assessment at time of index cardiac catheterization procedure.
Plan to share: Undecided
Eligibility is decided by the study team. Share this record with your doctor or contact the team directly.
Contact study teamGet an email when the registry record changes — status, dates, results — or when someone posts here.
Sign in to followQuestions and observations about this study, from anyone following it. Not medical advice, and not a channel to the study team — their contact details are on the registry record.
Sign in to join the discussion. Reading takes no account; posting does. You choose a display name, and a pseudonym is the default.
Nothing here yet. If you are running this trial, taking part in it, or weighing whether to, this is the place to say so.
China National Center for Cardiovascular Diseases