An interventional study of Kinesiotaping and Kinesiotaping(no tension) in Rounded Shoulder Posture and Kinesio Taping, sponsored by Selcuk University. Not yet recruiting. Open to participants aged 18 Years to 30 Years. Per ClinicalTrials.gov, last updated 2026-10-30.
Sponsored by Selcuk University · Not applicable, Interventional, and Diagnostic
Help build ClinicalTrials.gg — short surveys, remote interviews or testing, in your language. Take part →
Posture is maintained through the interaction of the musculoskeletal system, visual input, vestibular function, and proprioception to provide optimal balance with minimal energy expenditure. Various factors, including prolonged static sitting, unsuitable work environments, prolonged screen use, and low physical activity levels, may contribute to postural misalignment, particularly in student populations. Rounded shoulder posture is commonly associated with muscle imbalance, altered scapular alignment, pain in the neck and shoulder region, reduced range of motion, and functional limitations.
Kinesio taping is a physiotherapy intervention commonly used in orthopedic and musculoskeletal rehabilitation. Proposed effects include facilitation of proper muscular and fascial alignment, enhancement of proprioceptive feedback, and potential improvement in posture and movement quality. However, evidence regarding the immediate effects of kinesio taping on posture-related outcomes in individuals with rounded shoulder posture remains limited.
The purpose of this study is to evaluate the immediate effects of kinesio taping on posture, shoulder range of motion, and proprioception in students with rounded shoulder posture.
Selcuk University is the lead sponsor of 261 studies on the registry; 67 are open to participants now.
Counted across the registry records on this site, refreshed daily.
Go through the criteria one by one — yes, no or not sure — and take the list to your doctor or the study team. Kept in this browser only.
Exclusion Criteria:
Other: Kinesiotaping
Other: Kinesiotaping(no tension)
Elastic kinesiology tape will be applied by a licensed physiotherapist with experience in taping. With the participant standing in scapular retraction and neutral posture, a Y- or I-strip is placed from the anterior aspect of the acromion toward the spinous process of T10, with 30-40% stretch over the mid-portion and 0% tension on anchors. A second overlay strip will be applied along the same path with 30-40% stretch to augment the mechanical cue. Skin will be cleaned and dried; hair trimmed if needed. Tape will be rubbed to activate adhesive. Total application time ≈3-5 minutes. Tape remains in place during immediate (≤3 minutes) and short-term (\~30 minutes) assessments and is then removed. Adverse skin reactions will be monitored; tape will be removed immediately if irritation occurs.
The sham application is performed in the same area and configuration as the experimental arm; however, the strip is applied completely without tension (0%) along its length and does not provide a therapeutic mechanical cue. To maintain blinding, a second strip is applied along the same path with 0% tension and approximately 50% overlap. Skin preparation and application-removal procedures are identical to the experimental condition. The tape remains in place during the immediate (≤3 minutes) and short-term (\~30 minutes) assessments and is then removed.
posture assessment
PostureScreen Mobile is a valid and reliable mobile application that provides clinical-level postural assessment and analysis. The application uses photographs captured with a mobile device camera from anterior, lateral, and posterior views to evaluate body alignment, asymmetries, and postural deviations. Through visual analysis, the application performs angular and linear measurements to support objective postural evaluation. Planned measurement parameters include head translation (cm), head tilt angle, shoulder translation (cm), shoulder tilt angle, rib cage translation (cm), rib cage tilt angle, pelvic translation (cm), pelvic tilt angle, craniovertebral angle, kyphosis angle, and pelvic tilt. To ensure measurement consistency, the mobile device camera position will be standardized at a fixed distance and height for all participants. To enhance visibility and measurement accuracy, participants will be assessed barefoot and wearing only underwear during photographic capture.
Time frame: Baseline (pre-taping), immediately after application, and 30 minutes post-application.
Assessment of Joint Range of Motion
Shoulder range of motion will be assessed using the Goniometer Pro smartphone application, which provides valid and reliable angular measurements. Shoulder flexion and extension, abduction and adduction, and internal and external rotation will be evaluated. For each measurement, the smartphone will be securely fixed to the segment being assessed and calibrated to zero in the neutral position. During shoulder flexion and abduction measurements, the device will be positioned on the lateral surface of the humerus. For internal and external rotation measurements, the device will be placed on the dorsal surface of the forearm (ulna) with the shoulder positioned at 90 degrees of abduction. Participants will be aligned in standardized test positions, and compensatory movements, including scapular elevation and lumbar extension, will be manually restricted. The limb will be moved to the end range of the target motion, and the angular value will be recorded. Each measurement will be repeated
Time frame: Measured at baseline, immediately after taping (≤3 minutes), and 30 minutes post-taping; primary comparison is change from baseline
Pressure pain threshold
Pressure pain threshold measurements will be performed bilaterally on the dominant and nondominant sides using a digital algometer (JTECH Medical, Commander Echo). Due to increased activity and sensitivity of the upper trapezius muscles in individuals with rounded shoulder posture, assessments will be conducted on the upper trapezius muscle. During digital algometry, pressure will be applied to the measurement site at a constant rate of approximately 1 kg/s. The pressure value at which pain is first perceived will be recorded. Three consecutive measurements will be obtained, and the mean value will be used for analysis.
Time frame: Measured at baseline, immediately after taping (≤3 minutes), and 30 minutes post-taping; primary comparison is change from baseline
No study locations are listed for this record.
Plan to share: No
Start is estimated for Dec 2026; primary completion for Dec 2026, 0 months later.
Since we started tracking on Sep 25, 2026, the dates moved once, on Oct 30, 2026: start Mar 2026 → Dec 2026 and primary completion May 2026 → Dec 2026.
Earlier changes are on the record history on ClinicalTrials.gov ↗
How these figures are worked out, and which studies are left out of them.
From the registry record's own update history. This site started tracking changes on Sep 25, 2026; for anything earlier, see the record history on ClinicalTrials.gov ↗
This study is not yet recruiting, as verified in Jan 2026. You cannot join it, but the record below documents what was studied.
Get an email when the registry record changes — status, dates, results — or when someone posts here.
Sign in to followQuestions and observations about this study, from anyone following it. Not medical advice, and not a channel to the study team — their contact details are on the registry record.
Sign in to join the discussion. Reading takes no account; posting does. You choose a display name, and a pseudonym is the default.
Nothing here yet. If you are running this trial, taking part in it, or weighing whether to, this is the place to say so.