ClinicalTrials.gg
RecruitingNCT06548386Updated Sep 9, 2025

Feasibility and Accuracy of a Novel Pleural Drain Gas Analyzer in Detecting Air Leaks

An interventional study of Pleural gas analysis in Air Leak From Lung and Pneumothorax, sponsored by Lung Healing Technologies Inc. Recruiting at 1 site in United States. Open to participants aged 18 Years and older. Per ClinicalTrials.gov, last updated 2025-09-09.

Sponsored by Lung Healing Technologies Inc · Not applicable, Interventional, and Diagnostic

How we know

From the registry’s dates

  • Primary completion was expected by Jan 2026, 10 months ago, but the record still lists the study as recruiting.
  • Started Feb 2025; still recruiting 1 year 9 months later.

Help build ClinicalTrials.gg — short surveys, remote interviews or testing, in your language. Take part →

Phase
Not applicable
Study type
Interventional
Enrollment
33
Allocation
Not applicable
Ages
18 Years and older
Sex
All
01

Where this study stands

Counted across the records on this site · 2026-11-23

Among 32 studies in Pneumothorax with a site in United States — 6 open to participants now, 6 under way, none of them phase 3. Pneumothorax · United States.

Planned enrollment
11th of 16
33 · median 44
Started
2025
the only one that year
No phase
11 of 32
3 open now
Registered
30th of 32
by date

Among the 32 studies in Pneumothorax with a site in United States, this one is the 11th largest by planned enrollment of the 16 interventional ones that give a count, is the only one that started in 2025, is one of 11 with no phase, and was the 30th registered.

Pneumothorax

183 studies on the registry are indexed under Pneumothorax; 41 are open to participants now.

Browse Pneumothorax studies →

Open to participants now

6 of the 32 studies in Pneumothorax with a site in United States are open now. Recruiting first, the newest first:

All 6 open studies →

A study can be open while its sites in United States have not opened yet or have stopped. Only those recruiting at a site in United States →

Who these studies take

Of the 27 Pneumothorax studies recruiting now, 18 (67%) set no upper age limit and 5 (19%) stop at 75 or younger; 7 take children under 18; 7 take healthy volunteers.

This study: 18 Years and older · all sexes · no healthy volunteers.

The full table on the hub →

This tab as a report to print or save as PDF → With an account.

Was this useful?
Get alerts for this landscapeDownload CSVNarrow it in search →With an account: a weekly mail of what changed among 32 studies in Pneumothorax with a site in United States, or all of them as a file.
02

Study summary

The goal of this study is to assess the clinical feasibility of a novel, reusable, low cost gas analyzer that detects breath in chest drains in order to diagnose and heal air leaks. The investigators have developed prototype gas analyzers that attach to the outlet of any analog chest drain, and can be connected temporarily to the sampling port. They detect breath by measuring CO2, O2, and pressure, in order to supplement the information provided by the bubbles in the water seal.

Read the detailed description

Tests on patients in 2013 at Northwestern demonstrated that gas analysis can help diagnose and heal air leaks by detecting breath in chest drains, as documented in the investigator's patents and peer-reviewed publications. CO2 is 100 times higher in the lung than ambient, and O2 the same amount lower in ppm. The length of time that it takes to detect breath at the outlet is related to the size of the air leak. O2 is available next to every bed, often used in recovery, and when high O2 is quickly detected at the sampling port, the only source can be an active air leak.

The primary aim is to assess whether the device can accurately measure changes in gas flow from an analog pleural drain and whether this accurately detects pleural air leaks.

Specific aim 1: To determine whether the gas analyzer device can measure changes in exhaled gas levels and if this can distinguish true air leaks from false air leaks.

Sub aim 1: Assess how patient characteristics such as extent of resection, pre-existing conditions such as COD, lung function test, etc, affect the efficacy of the device.

Specific aim 2: Compare the accuracy of pleural air leak measured via gas analysis to the accuracy of pleural air leak detection as measured by standard VI.

The hypothesis is that the prototype pleural gas analyzer, through detection of carbon dioxide and oxygen levels, can distinguish true air leaks from false air leaks more accurately than the traditionally practiced method of Visual Inspection of bubbles in the chest drainage unit (VI).

Study Endpoints:

The primary end point of this study is detection of air leak, either by VI or prototype pleural gas analysis.

True Air Leak Definition:

  1. Both visual inspection and pleural gas analysis demonstrate an air leak
  2. Development of a pneumothorax at any point up to 4 weeks after chest tube removal
  3. Pneumothorax develops during a clamp trial to assess for true air leak (failed clamp trial)
  4. Patient discharged home with chest tube due to clinical concern (even in absence of clamp trial) of ongoing air leak
  5. Development of clinically significant subcutaneous emphysema either with a chest tube in place or after chest tube removal (defined as an increase beyond initial post op, observable to patient or care team) Secondary endpoint is comparison in accuracy in detection of air leak between VI and gas analysis.
03

Conditions studied

  • Air Leak From Lung
  • Pneumothorax

Browse trials for

Keywords

  • alveolopleural fistula
04

Who can participate

Ages eligible
18 Years and older
Sexes eligible
All
Accepts healthy volunteers
No

Go through the criteria one by one — yes, no or not sure — and take the list to your doctor or the study team. Kept in this browser only.

Inclusion criteria

  1. Patients who are scheduled for thoracic surgery and expected to have chest tube placed
  2. For patients who are unable to sign consent, but meet all of the inclusion criteria and none of the exclusion criteria, a legally appointed representative (LAR) will be allowed to sign consent for that patient
  3. Patients that provide for the study
  4. Patients >18 years old

Exclusion criteria

Exclusion Criteria:

  1. Patients with hemodynamic instability
  2. Pregnant patients
  3. Prisoners
  4. Individuals who are not yet adults
Terms in these criteria, in plain language(1)

Underlined terms in the criteria open these too. Explained by clinicaltrials.gg, not part of the registry record. The study team decides who can take part.

Informed consent

Before you join, the study team explains what taking part involves — its purpose, what happens, the risks and possible benefits — and answers your questions, so you can decide freely. Consent is usually recorded on a form (the informed consent form, ICF) signed by you or, where the law allows, by someone legally authorized to decide for you.

You can keep asking questions during the study, you are told of new information that matters, and you can choose to leave at any time.

05

Study design

Phase
Not applicable
Primary purpose
Diagnostic
Allocation
Not applicable
Intervention model
Single group
Masking
None (open label)
Enrollment
33 participants (estimated)

Interventions

  • DevicePleural gas analysis

    Patients enrolled in this study will undergo both VI and pleural gas analysis to assess for air leak following surgical chest tube placement. For pleural gas analysis, an outlet gas analyzer will be kept on the outlet port of the chest drain for the entire duration of time that a chest tube is in place. We plan to collect both continuous data, looking for intermittent spikes and gas changes, along with episodic data collected during specific air leak assessments. The gas analyzer may better be able to measure an air leak during these specific procedures conducted twice per day, but it will also be used at the outlet port of the chest drain the rest of the time to continuously check for an air leak throughout the hospital stay.

06

What researchers measure

Primary outcomes

  1. Accuracy alone

    Whether gas analysis can accurately assess for air leak

    Time frame: One year

Secondary outcomes

  1. Using VI as well

    Comparison of accuracy in air leak assessment between gas analysis and visual inspection

    Time frame: One year

07

Study locations

1 of 1 sites recruiting
08

References and documents

Individual participant data

Plan to share: No

No publications or documents are linked to this record.

09

Timeline

Tracking since Sep 25, 2026
ElapsedEstimatedEstimated, not yet reachedSimilar studies: half by the dot; the band is the middle halfHalf of similar studies reached it by the dot; the band is the middle half, from a quarter to three quarters

Started Feb 2025 (actual). Primary completion is estimated for Jan 2026, 11 months after the start.

Of 43 interventional studies with no phase under Pneumothorax, half reached primary completion within 26 months of starting (the median), counting those still running; a quarter within 14 and three quarters within 34. This study's planned 11 months is below that.

How these figures are worked out, and which studies are left out of them.

Registered
Aug 8, 2024
First posted
Aug 12, 2024
StartActual
Feb 5, 2025
Primary completionEst.
Jan 2026
CompletionEst.
Jun 2026
Last update
Sep 9, 2025
What these dates mean
Start.
When the first participant enrolled; while estimated, when the study expects to open to recruitment.
Primary completion.
When the last participant was examined or treated to collect data for the study's main question, its primary outcome. A study that stopped early gives the date its data collection stopped.
Completion.
When the last participant's last visit took place, for every outcome, secondary ones and side effects included: the end of the study. Often later than primary completion, sometimes the same day.
Actual and Est.
Actual means the registry says the date has happened. Est. (estimated) is a date the sponsor plans or expects. It can still move, and the sponsor is expected to change it to actual once it has passed.
No changes since tracking began. The registry record was last updated on Sep 9, 2025, before this site started recording changes on Sep 25, 2026. Its history is on ClinicalTrials.gov ↗
10

Registry details

Key details

Study ID
NCT06548386
Lead sponsor
Lung Healing Technologies Inc
Responsible party
Sponsor
First posted
Aug 12, 2024
Start date
Feb 5, 2025
Primary completion
Jan 2026 (estimated)
Completion
Jun 2026 (estimated)
Last update
Sep 9, 2025

Study contacts

Dan Dodd
Contact
ddodd@lunghealingtechnologies.com
3033242264

Oversight

FDA-regulated drug
No
FDA-regulated device
Yes
View the source record on ClinicalTrials.gov ↗

Interested in this study?

Eligibility is decided by the study team. Share this record with your doctor or contact the team directly.

Contact study team

Follow this study

Get an email when the registry record changes — status, dates, results — or when someone posts here.

Sign in to follow

Discussion

Questions and observations about this study, from anyone following it. Not medical advice, and not a channel to the study team — their contact details are on the registry record.

Sign in to join the discussion. Reading takes no account; posting does. You choose a display name, and a pseudonym is the default.

Nothing here yet. If you are running this trial, taking part in it, or weighing whether to, this is the place to say so.

Start the discussion