ClinicalTrials.gg
RecruitingNCT06298604Updated Mar 22, 2024

Motorized Fine Needle Biopsy vs Standard Needles

An interventional study of EUS-guided standard fine needle biopsy and EUS-guided motorized fine needle biopsy in Pancreas Disease and Liver Diseases, sponsored by Instituto Ecuatoriano de Enfermedades Digestivas. Recruiting at 1 site in Ecuador. Open to participants aged 18 Years to 99 Years. Per ClinicalTrials.gov, last updated 2024-03-22.

Sponsored by Instituto Ecuatoriano de Enfermedades Digestivas · Not applicable, Interventional, and Diagnostic

From the registry’s dates

  • Primary completion was expected by Oct 2024, 2 years 1 month ago, but the record still lists the study as recruiting.
  • Started Dec 2023; still recruiting 2 years 11 months later.
Phase
Not applicable
Study type
Interventional
Enrollment
60
Allocation
Randomized
Ages
18 Years to 99 Years
Sex
All
01

Study summary

Recent improvements in punctures techniques and needles now allow for the collection of high-quality specimens comparable to core needle biopsy. A newly developed motorized fine needle biopsy (mFNB), the Precision-GI (Limaca, Israel) promises intact tissue acquisition without sample damage, relying on controlled axial tissue cutting and high-speed rotational coring for optimized tissue acquisition.

Given the advancement mentioned, the investigators aim to compare the performance of the mFNB with the standard needle during the acquisition of endoscopic ultrasound (EUS)-guided pancreatic and liver specimens through a prospective, interventional, single-center trial. The study will consist of two groups of patients: one assigned to the standard fine needle biopsy (FNB) and the other to the mFNB. The primary study outcomes will include sample quality (core integrity), and diagnostic accuracy.

Read the detailed description

The development of Endoscopic ultrasound-guided tissue acquisition (EUS-TA) has been remarkable. Initially focused on obtaining samples from the pancreas, it has expanded significantly to include various organs adjacent to the gastrointestinal system (i.e., liver, lymph nodes, adrenal glands).

One of the key advancements in EUS-TA involves the shift from cytological analysis, with fine-needle aspiration (FNA), to histological and even genetic evaluations, with fine-needle biopsies (FNB). FNB addresses some limitations associated with FNA, such as low tumor cellularity and the inability to retain cellular architecture.

Recent improvements in puncture techniques and needles, allow for the collection of high-quality specimens, comparable to core needle biopsy, to achieve standards for specimen adequacy (i.e., intact liver cores of at least 15-20 mm with a complete portal triad count of 11). Some current available needle designs include the crown type, flanged type, 20 Gauge FNB needles with forward-faced core traps, and the fork-tip needles, demonstrating high diagnostic accuracy and a low rate of adverse events.

The Precision-GI is a new motorized fine needle (mFNB) developed by LIMACA Medical in Israel for EUS-guided FNB. It operates using a battery-powered motor that enables controlled axial tissue cutting and high-speed rotational coring for optimized tissue acquisition. Moreover, a sharp stylet facilitates crossing through the gastrointestinal wall, allowing for the reach of target lesions. The rotational electromechanical cutting movement into the lesion promises intact motorized tissue acquisition without sample damage.

In the present study, the investigators aim to compare the performance of the mFNB with the standard needle during the acquisition of EUS-guided pancreatic and liver specimens. The study will consist of two groups of patients: one assigned to the standard fine needle biopsy (FNB) and the other to the mFNB. The primary study outcomes will include sample quality (core integrity), and diagnostic accuracy.

02

Conditions studied

  • Pancreas Disease
  • Liver Diseases

Keywords

  • Fine-needle biopsy
  • Endosonography
  • liver
  • pancreas
  • pathology
03

In context

Pancreatic Diseases

184 studies on the registry are indexed under Pancreatic Diseases; 63 are open to participants now.

This study's planned enrollment of 60 is below the median of 96 across 104 interventional studies indexed under Pancreatic Diseases.

Browse Pancreatic Diseases studies →

Lead sponsor

Instituto Ecuatoriano de Enfermedades Digestivas is the lead sponsor of 39 studies on the registry; 10 are open to participants now.

Counted across the registry records on this site, refreshed daily.

04

Who can participate

Ages eligible
18 Years to 99 Years
Sexes eligible
All
Accepts healthy volunteers
No

Go through the criteria one by one — yes, no or not sure — and take the list to your doctor or the study team. Kept in this browser only.

Inclusion criteria

  • Patients between 18 and 99 years
  • Patients referred to our center who require EUS-guided liver or pancreas .
  • Male or female patients.
  • Patients able to give consent

Exclusion criteria

Exclusion Criteria:

  • Pregnancy or nursing
  • Patients with coagulation disorders ( \<50.000/mm3, (INR) >2)
  • Any underlying medical condition that contraindicates EUS-guided fine needle such as anatomical alterations, significant gastric outlet obstruction, collateral intervening vessels.
Terms in these criteria, in plain language(3)

Underlined terms in the criteria open these too. Explained by clinicaltrials.gg, not part of the registry record. The study team decides who can take part.

Biopsy and archival tissue

A biopsy takes a small piece of tissue to examine. “Archival tissue” is a sample already taken, for example at diagnosis, and kept by the hospital.

Whether a stored sample will do depends on when it was taken, how much there is and what the study needs. Ask whether the study accepts your stored sample or needs a new biopsy.

Platelets

Blood cells that help blood clot. Too few raises the risk of bleeding and bruising. A usual adult range is about 150–400 × 10⁹/L (150,000–400,000 per µL); each lab has its own reference range.

INR, PT and aPTT (clotting tests)

Blood tests of how long blood takes to clot. The INR is the prothrombin time (PT) put on a common scale; about 1 is usual for someone not taking a blood thinner.

Criteria often make an exception for people on a blood thinner such as warfarin, whose INR is raised on purpose.

05

Study design

Phase
Not applicable
Primary purpose
Diagnostic
Allocation
Randomized
Intervention model
Parallel assignment
Masking
Single (Care provider)
Enrollment
60 participants (estimated)

Study arms

  • Active comparator
    Standard EUS-guided FNB

    Patients scheduled for EUS-guided liver or pancreas biopsy will undergo the procedure using a standard 19-gauge needle

    Device: EUS-guided standard fine needle biopsy

  • Experimental
    Motorized EUS-guided FNB

    Patients scheduled for EUS-guided liver or pancreas biopsy will undergo the procedure using a motorized 20-gauge needle.

    Device: EUS-guided motorized fine needle biopsy

Interventions

  • DeviceEUS-guided standard fine needle biopsy

    Using the echoendoscope, a pancreatic lesion or liver parenchyma will be identified, and a 19-gauge standard fine needle biopsy device (Boston Scientific, USA) is inserted on it to obtain the sample or specimen.

  • DeviceEUS-guided motorized fine needle biopsy

    Using the echoendoscope, a pancreatic lesion or liver parenchyma will be identified, and a 20-gauge motorized fine needle biopsy device (Limaca, Israel) is inserted on it to obtain the sample or specimen.

06

What researchers measure

Primary outcomes

  1. Endoscopic ultrasound fine needle biopsy sample quality

    Based on tissue "core"; Tissue core is defined as a architecturally intact piece of at least 550 micron in the greatest axis. The tissue core will be evaluated in both groups by the pathologist immediately after its acquisition.

    Time frame: Up to two hours after the procedures

  2. Diagnostic accuracy according to histological analysis

    Proportion of subjects with a definitive diagnosis based on the number of passes and throws for tissue acquisition.

    Time frame: Up to one week

Secondary outcomes

  1. Tissue blood contamination

    Evaluation of tissue blood contamination will be based on a sample quality score: 1. Only blood 2. High (\>50% of the surface of the slide) 3. Moderate (25%-50% of the surface of the slide) 4. Low (\<25% of the surface of the slide)

    Time frame: Up to one hour

Other outcomes

  1. Time efficiency during tissue acquisition

    The tissue from identifying the lesion to obtaining the sample. It will be calculated in minutes

    Time frame: Up to two hours

  2. Rate of liver specimen adequacy

    Intact liver cores of at least 15-20 mm with a complete portal triad count of 11

    Time frame: Up to 1 week

  3. Rate of adverse events associated with the procedure

    Adverse event associated with the procedure, including transprocedural, early, and late post-procedural occurrence

    Time frame: Up to 6 months

  4. Quality of cytologic sample

    The quality of the cytologic sample will be scored according to the pathologist criteria as: 0= insufficient material for cytologic interpretation 1. sufficient material for limited cytologic interpretation 2. sufficient material for adequate cytologic interpretation

    Time frame: Up to 2 hours

07

Study locations

1 of 1 sites recruiting
  • Instituto Ecuatoriano de Enfermedades Digestivas (IECED)
    Guayaquil, 090505, Ecuador
    Recruiting
    • Carlos Robles-Medranda, MD FASGE · Contactcarlosoakm@yahoo.es · +593989158865
    • Carlos Robles-Medranda, MD FASGE · Principal investigator
    • Raquel Del Valle, MD · Sub investigator
    • Maria Egas-Izquierdo, MD · Sub investigator
    • Jorge Baquerizo-Burgos, MD · Sub investigator
    • Domenica Cunto, MD · Sub investigator
    • Juan Alcivar-Vasquez, MD · Sub investigator
    • Daniela Tabacelia, MD · Sub investigator
    • Martha Arevalo-Mora, MD · Sub investigator
    • Miguel Puga-Tejada, MD · Sub investigator
    • Gustavo Rubio, MD · Sub investigator
    • Hannah Pitanga-Lukashok, MD · Sub investigator
08

References and documents

Publications

  • Mendoza Ladd A, Casner N, Cherukuri SV, Garcia C, Padilla O, Dwivedi A, Hakim N. Fine Needle Biopsies of Solid Pancreatic Lesions: Tissue Acquisition Technique and Needle Design Do Not Impact Specimen Adequacy. Dig Dis Sci. 2022 Sep;67(9):4549-4556. doi: 10.1007/s10620-021-07316-4. Epub 2021 Dec 2. PubMed 34859313 ↗
  • Di Mitri R, Mocciaro F, Antonini F, Scimeca D, Conte E, Bonaccorso A, Scibetta N, Unti E, Fornelli A, Giorgini S, Binda C, Macarri G, Larghi A, Fabbri C. Stylet slow-pull vs. standard suction technique for endoscopic ultrasound-guided fine needle biopsy in pancreatic solid lesions using 20 Gauge Procore needle: A multicenter randomized trial. Dig Liver Dis. 2020 Feb;52(2):178-184. doi: 10.1016/j.dld.2019.08.023. Epub 2019 Oct 7. PubMed 31601535 ↗
  • Fujita A, Ryozawa S, Tanisaka Y, Ogawa T, Saito Y, Katsuda H, Miyaguchi K, Yasuda M, Araki R, Mashimo Y, Tashima T, Nakano Y, Terada R, Jinushi R, Mizuide M. Comparison of Fork-tip and Franseen needles for endoscopic ultrasound-guided fine-needle biopsy in pancreatic solid lesions: A propensity-matched analysis. DEN Open. 2022 Jun 28;3(1):e147. doi: 10.1002/deo2.147. eCollection 2023 Apr. PubMed 35898843 ↗

Individual participant data

Plan to share: Undecided

09

Updates

Tracking since Sep 25, 2026
No changes since tracking began. The registry record was last updated on Mar 22, 2024, before this site started recording changes on Sep 25, 2026. Its history is on ClinicalTrials.gov ↗
10

Registry details

Key details

Study ID
NCT06298604
Lead sponsor
Instituto Ecuatoriano de Enfermedades Digestivas
Responsible party
Carlos Robles-Medranda (Head of the Endoscopy Division, Instituto Ecuatoriano de Enfermedades Digestivas) — Principal investigator
First posted
Mar 7, 2024
Start date
Dec 9, 2023
Primary completion
Oct 9, 2024 (estimated)
Completion
Dec 9, 2024 (estimated)
Last update
Mar 22, 2024

Oversight

Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No
View the source record on ClinicalTrials.gov ↗

Interested in this study?

Eligibility is decided by the study team. Share this record with your doctor or contact the team directly.

No contact was published for this record. The registry link below has the sponsor’s details.

Follow this study

Get an email when the registry record changes — status, dates, results — or when someone posts here.

Sign in to follow

Discussion

Questions and observations about this study, from anyone following it. Not medical advice, and not a channel to the study team — their contact details are on the registry record.

Sign in to join the discussion. Reading takes no account; posting does. You choose a display name, and a pseudonym is the default.

Nothing here yet. If you are running this trial, taking part in it, or weighing whether to, this is the place to say so.

Start the discussion