An interventional study of Jump System Traser® cup and Jump System HAX-Pore® cup in Total Hip Arthroplasty, sponsored by Permedica spa. Recruiting at 2 sites in Italy. Open to participants aged 40 Years to 85 Years, including healthy volunteers. Per ClinicalTrials.gov, last updated 2025-09-02.
Sponsored by Permedica spa · Not applicable, Interventional, and Treatment
The goal of this randomized controlled trial is to measure the periprosthetic bone mineral density changes around a 3D-printed highly-porous titanium acetabular cup used in primary total hip arthroplasty compared to a standard hydroxyapatite/titanium plasma-sprayed acetabular cup up to 2-year follow-up.
In joint arthroplasty, the need to use devices with highly-porous structures even more close to cancellous bone, arises from the need of optimal implant primary stability and osseointegration to guarantee long term longevity of the prosthetic implant.
After decades of clinical use of highly-porous tantalum (Trabecular Metal) acetabular components in total hip arthroplasty with excellent results, new highly-porous titanium structures have been developed and introduced in the market thanks to the additive manufacturing technology.
This study aims to investigate how bone remodeling occurs after primary total hip arthroplasty around a highly-porous trabecular-irregular acetabular cup, 3D-printed with selective laser melting, in comparison with a standard hydroxyapatite/titanium plasma-sprayed cup with the same design. The null hypothesis, which the study aims to reject, is that there is no difference in bone mineral density changes between highly-porous and traditional plasma-sprayed cups.
Overall 50 patients will be enrolled to be 1:1 randomized for receiving the investigational cup or the control cup in two centers.
Periprosthetic bone mineral density will be measured by DEXA (Dual-Energy X-ray Absorptiometry) around the acetabular cup according to four ROI (Region Of Interest). DEXA scans will be taken at different time-points up to 2-year follow-up. DEXA scan taken before patient discharge will be used as baseline.
Patients will be assessed also for clinical and radiological results, with focus on osseointegration signs of the acetabular cup.
Permedica spa is the lead sponsor of 4 studies on the registry; 1 is open to participants now.
Counted across the registry records on this site, refreshed daily.
Exclusion Criteria:
25 patients receiving unilateral primary total hip arthroplasty with the Jump System Traser® acetabular cup, a 3D-printed highly-porous titanium cup
Device: Jump System Traser® cup
25 patients receiving unilateral primary total hip arthroplasty with the Jump System HAX-Pore® acetabular cup, a standard hydroxyapatite/titanium plasma-sprayed cup
Device: Jump System HAX-Pore® cup
Press-fit, cementless, 3D-printed, highly-porous trabecular titanium acetabular cup
Press-fit, cementless, hydroxyapatite/titanium plasma-sprayed acetabular cup
BMD - ROI 1
Periprosthetic BMD (bone mineral density) measured by DEXA in ROI (region of interest) 1 (above the acetabular cup)
Time frame: Preoperative, 1 week postoperatively, 3-month, 6-month,12-month, and 24-month follow-up
BMD - ROI 2,3,4
Periprosthetic BMD (bone mineral density) measured by DEXA in ROI (region of interest) 2, 3 and 4 (behind and below the acetabular cup)
Time frame: Preoperative, 1 week postoperatively, 3-month, 6-month,12-month, and 24-month follow-up
Harris hip score
Clinical score for hips undergoing total hip arthroplasty. The Harris hip score ranges from 0 to 100, where 100 indicates the best outcome possible for the patient.
Time frame: Preoperative,12-month, and 24-month follow-up
Moore's osseointegration signs
Five radiographic signs around the acetabular cup revealing the stability and osseointegration status of cementless component: (1) absence of radiolucent lines; (2) presence of a superolateral buttress; (3) medial stress-shielding; (4) radial trabeculae; and (5) an inferomedial buttress. The presence of 3 to 5 signs visible on anterior-posterior radiograph of the hip indicates 97% probability of a well osseointegrated cup. The presence of 1 or no signs indicates 83% probability of unstable, not osseointegrated cup.
Time frame: 12-month and 24-month follow-up
Plan to share: No
Eligibility is decided by the study team. Share this record with your doctor or contact the team directly.
Contact study teamGet an email when the registry record changes — status, dates, results — or when someone posts here.
Sign in to followQuestions and observations about this study, from anyone following it. Not medical advice, and not a channel to the study team — their contact details are on the registry record.
Sign in to join the discussion. Reading takes no account; posting does. You choose a display name, and a pseudonym is the default.
Nothing here yet. If you are running this trial, taking part in it, or weighing whether to, this is the place to say so.
Permedica spa