An observational study in Tendinopathy, sponsored by University Hospital Bispebjerg and Frederiksberg. Recruiting at 1 site in Denmark. Open to participants aged 18 Years to 70 Years, including healthy volunteers. Per ClinicalTrials.gov, last updated 2026-01-22.
Sponsored by University Hospital Bispebjerg and Frederiksberg · Observational
The goal of this observational study is to test whether a new ultrasound method, called SUper Resolution ultrasound imaging of Erythrocytes (SURE), can image the small blood vessels found in tendons of persons with a tendon overuse injury (tendinopathy). The main questions it aims to answer are:
Participants will receive a non-invasive ultrasound examination of their Achilles (heel) or patellar (knee) tendon, using an advanced high frequency research ultrasound system.
Researchers will compare participants with either an Achilles or patellar tendon overuse injury to participants with healthy tendons, to see if there are distinct differences in the blood vessels that could help diagnose and treat the injuries.
Studies have reported an enlargement of the microvascular network in human tendons with a chronic overuse injury (tendinopathy). Ingrowth of new vessels and accompanying nerves have been proposed to be the cause of painful symptoms in patients with tendinopathy. Doppler ultrasound is the most common imaging modality to clinically investigate tendon neovascularization. This measurement is clinically useful, but its sensitivity is limited, which means that no Doppler flow is visible in healthy tendons despite invasive techniques having shown the presence of such flow. The lack of sensitivity in Doppler ultrasound means that it is impossible to accurately follow the progression from the healthy state (with zero Doppler) to a chronic state (with detectable Doppler), as well as the reverse process during healing of the injury.
The present study is designed to evaluate an ultrasound method called Super-resolution ultrasound imaging of erythrocytes (SURE), which is a new imaging technique for visualization and quantification of the microvasculature of tissues. The method is built on a technique called super-resolution ultrasound imaging (SRI), where an ultrasound contrast agent is injected into the bloodstream and tracked inside the vessels to build an image of the microvasculature. With SURE, no contrast agent is needed; it relies only on standard ultrasound to track the erythrocytes and thereby avoid invasive procedures.
The aim of this study is to determine the applicability of the SURE technique to detecting microvascular flow changes with tendinopathy by quantifying flow parameters in SURE images of healthy and tendinopathic tissues.
The study is designed as a cross-sectional, single-center, diagnostic, case-control trial on participants who are either healthy or have had a tendinopathy in their Achilles or patellar tendon. A formal sample size estimate cannot be made since the SURE method has not been clinically applied before, the sample sizes are therefore based on our experience with other outcomes for this patient group.
The study-specific medical device consists of 2 main components: a scanner system and an ultrasound probe.
Both components are marked for conformity within the European Union (CE). The entire system (including the probe and scanner system) would classify as a Class IIa medical device, but it has not gone through a notified body as the system is not intended for commercial use.
For measurements, the participant is placed on a bed and scanned with conventional ultrasound to locate the region of tendon injury (or the thickest part of the tendon for healthy participants) and characterize it with grey-scale and Doppler imaging. The region of interest is marked on the skin and the ultrasound probe is affixed to the tendon at the specified location using a custom holder to minimize motion. The probe is then be disconnected from the conventional ultrasound scanner and connected to the Vantage 256™ scanner to record SURE images. Image data may be collected for up to 1 minute. Two scans at the same location are used for estimating repeatability. The imaging setup and image processing will be adjusted to maximize quality of the SURE images. From the images, the vessel density, and potentially other parameters (flow rate, flow orientation, vessel dimensions etc.) may be determined.
397 studies on the registry are indexed under Tendinopathy; 77 are open to participants now.
This study's planned enrollment of 135 is above the median of 61 across 50 observational studies indexed under Tendinopathy.
Browse Tendinopathy studies →University Hospital Bispebjerg and Frederiksberg is the lead sponsor of 69 studies on the registry; 18 are open to participants now.
Counted across the registry records on this site, refreshed daily.
Healthy participants:
Persons who have no self-reported current or historical injuries to the tendon and surrounding tissue, and display no symptoms of tendinopathy upon examination.
Participants with tendinopathy:
Persons who have no self-reported current or historical injuries to the tendon and surrounding tissue, aside from a uni- or bi-lateral tendinopathy of the patellar or Achilles tendon based on two clinical criteria: Tendon pain during physical activity and Tendon pain on local palpation.
Go through the criteria one by one — yes, no or not sure — and take the list to your doctor or the study team. Kept in this browser only.
Exclusion Criteria:
Underlined terms in the criteria open these too. Explained by clinicaltrials.gg, not part of the registry record. The study team decides who can take part.
Weight in kilograms divided by height in metres squared. Example: 70 kg and 1.75 m gives 70 ÷ (1.75 × 1.75) ≈ 22.9.
What counts as overweight or obesity differs between countries (some use lower cut-offs), so go by the range the study states.
Before you join, the study team explains what taking part involves — its purpose, what happens, the risks and possible benefits — and answers your questions, so you can decide freely. Consent is usually recorded on a form (the informed consent form, ICF) signed by you or, where the law allows, by someone legally authorised to decide for you.
You can keep asking questions during the study, you are told of new information that matters, and you can choose to leave at any time.
BMI (body mass index)
Weight in kilograms divided by height in metres squared. Example: 70 kg and 1.75 m gives 70 ÷ (1.75 × 1.75) ≈ 22.9.
What counts as overweight or obesity differs between countries (some use lower cut-offs), so go by the range the study states.
Explained by clinicaltrials.gg, not part of the registry record. The study team decides who can take part.
Informed consent
Before you join, the study team explains what taking part involves — its purpose, what happens, the risks and possible benefits — and answers your questions, so you can decide freely. Consent is usually recorded on a form (the informed consent form, ICF) signed by you or, where the law allows, by someone legally authorised to decide for you.
You can keep asking questions during the study, you are told of new information that matters, and you can choose to leave at any time.
Explained by clinicaltrials.gg, not part of the registry record. The study team decides who can take part.
Healthy Controls. Super-Resolution Ultrasound Imaging of Erythrocytes (SURE) of both Achilles and Patellar Tendons.
Diagnostic Test: Super-Resolution Ultrasound Imaging of Erythrocytes (SURE)
Patients with Achilles Tendinopathy. Super-Resolution Ultrasound Imaging of Erythrocytes (SURE) of Achilles Tendons.
Diagnostic Test: Super-Resolution Ultrasound Imaging of Erythrocytes (SURE)
Patients with Patellar Tendinopathy. Super-Resolution Ultrasound Imaging of Erythrocytes (SURE) of Patellar Tendons.
Diagnostic Test: Super-Resolution Ultrasound Imaging of Erythrocytes (SURE)
Research ultrasound sequence for tracking erythrocytes and thereby generating a super-resolution image of the vasculature.
Also known as: Ultrasonography
Vessel density (all)
Mean difference in blood vessel density detected by SURE imaging, between the healthy and tendinopathic group (across both patellar and Achilles).
Time frame: day 0 (the study is cross-sectional)
Repeatability (vessel density)
Intraclass correlation of blood vessel density detected by SURE imaging in repeated ultrasound scans of the same tendon across all participants.
Time frame: day 0 (the study is cross-sectional)
Vessel density (PT/AT)
Mean difference in blood vessel density detected by SURE imaging, between the healthy and tendinopathic group (within the patellar or Achilles individually).
Time frame: day 0 (the study is cross-sectional)
Other quantifiable measures of microvasculature
To-be-defined quantitative image analysis outcome of the microvasculature (due to the novelty of the method, the exact image analysis pipeline is not yet defined)
Time frame: day 0 (the study is cross-sectional)
Plan to share: Undecided — Due to the developmental nature of the study, the exact outcomes are currently poorly defined and the format in which they may be shared is therefore difficult to predict. We do intent to share individual participant data (IPD) in the form of to-be-defined image analysis outcomes as supplementary to relevant publications.
No publications or documents are linked to this record.
Eligibility is decided by the study team. Share this record with your doctor or contact the team directly.
Contact study teamGet an email when the registry record changes — status, dates, results — or when someone posts here.
Sign in to followQuestions and observations about this study, from anyone following it. Not medical advice, and not a channel to the study team — their contact details are on the registry record.
Sign in to join the discussion. Reading takes no account; posting does. You choose a display name, and a pseudonym is the default.
Nothing here yet. If you are running this trial, taking part in it, or weighing whether to, this is the place to say so.
University Hospital Bispebjerg and Frederiksberg