An observational study in Pseudophakia, sponsored by Berkeley Eye Center. Completed at 1 site in United States. Open to participants aged 40 Years and older, including healthy volunteers. Per ClinicalTrials.gov, last updated 2025-05-23.
Sponsored by Berkeley Eye Center · Observational
Background:
Hypothesis:
Unmet Medical Need:
54 studies on the registry are indexed under Pseudophakia; 8 are open to participants now.
This study's enrollment of 230 is above the median of 71 across 26 observational studies indexed under Pseudophakia.
Browse Pseudophakia studies →Berkeley Eye Center is the lead sponsor of 8 studies on the registry; 2 are open to participants now.
Counted across the registry records on this site, refreshed daily.
Patients with healthy eyes and uncomplicated bilateral implantation of Panoptix IOLs or Synergy IOLs.
Go through the criteria one by one — yes, no or not sure — and take the list to your doctor or the study team. Kept in this browser only.
Exclusion Criteria:
Underlined terms in the criteria open these too. Explained by clinicaltrials.gg, not part of the registry record. The study team decides who can take part.
Before you join, the study team explains what taking part involves — its purpose, what happens, the risks and possible benefits — and answers your questions, so you can decide freely. Consent is usually recorded on a form (the informed consent form, ICF) signed by you or, where the law allows, by someone legally authorised to decide for you.
You can keep asking questions during the study, you are told of new information that matters, and you can choose to leave at any time.
Judged by the study doctor to matter for your health or for the study. It is a doctor’s decision, so ask the study team if you are unsure whether something counts.
A weakened immune system. It can come from an illness, such as HIV or some blood cancers, or from medicines that turn the immune system down, for example after an organ transplant or for an autoimmune disease; steroids at higher doses count.
Read whether the line is about a condition or about medicines, and which medicines and doses it means.
Informed consent
Before you join, the study team explains what taking part involves — its purpose, what happens, the risks and possible benefits — and answers your questions, so you can decide freely. Consent is usually recorded on a form (the informed consent form, ICF) signed by you or, where the law allows, by someone legally authorised to decide for you.
You can keep asking questions during the study, you are told of new information that matters, and you can choose to leave at any time.
Explained by clinicaltrials.gg, not part of the registry record. The study team decides who can take part.
Clinically significant
Judged by the study doctor to matter for your health or for the study. It is a doctor’s decision, so ask the study team if you are unsure whether something counts.
Explained by clinicaltrials.gg, not part of the registry record. The study team decides who can take part.
Immunosuppression
A weakened immune system. It can come from an illness, such as HIV or some blood cancers, or from medicines that turn the immune system down, for example after an organ transplant or for an autoimmune disease; steroids at higher doses count.
Read whether the line is about a condition or about medicines, and which medicines and doses it means.
Explained by clinicaltrials.gg, not part of the registry record. The study team decides who can take part.
Patients will have had bilateral implantation of PanOptix IOLs with the toric and/or non-toric models at the time of uncomplicated cataract surgery.
Diagnostic Test: Visual Acuity · Diagnostic Test: Defocus Curve · Diagnostic Test: Halo and Glare testing · Other: Patient Questionnaires
Patients will have had bilateral implantation of Synergy IOLs with the toric and/or non-toric models at the time of uncomplicated cataract surgery.
Diagnostic Test: Visual Acuity · Diagnostic Test: Defocus Curve · Diagnostic Test: Halo and Glare testing · Other: Patient Questionnaires
Measurement of distance, intermediate and near visual acuity.
Measurement of visual acuity performed from +1.00 to -4.00 in 0.50 diopter steps and with +0.25 and -0.25 added.
Measurement to quantify degree of visual loss caused by either halo and/or glare.
Also known as: VS Halo & Glare (visu-med.com)
Patients will complete a series of questionnaires to record self-reported visual disturbances, visual acuity satisfaction, level of spectacle independence and any issues with glare, halos, and/or starbursts.
Also known as: IOLSAT, QUVID and Self-Reported Visual Disturbance Questionnaire
Binocular DCNVA (Distance Corrected Near Visual Acuity) at 40cm
Binocular DCNVA Visual acuity testing will be measured in LogMar and all study technicians and evaluators will be masked. A summary of the data will be prepared for all subjects and categorized by the lens implanted. Variables measured on a continuous scale will be summarized to include sample size as well as the mean, standard deviation, median, minimum and maximum.
Time frame: 3 months post operatively
Binocular Corrected Distance Visual Acuity (CDVA) Measured at 4m.
Binocular CDVA measured at 4m. Visual acuity testing will be measured in LogMar and all study technicians and evaluators will be masked. A summary of the data will be prepared for all subjects and categorized by the lens implanted. Variables measured on a continuous scale will be summarized to include sample size as well as the mean, standard deviation, median, minimum and maximum.
Time frame: 3 months post operatively
Binocular Distance Corrected Intermediate Visual Acuity (DCIVA) Measured at 60cm.
Binocular DCIVA measured at 60cm. Visual acuity testing will be measured in LogMar and all study technicians and evaluators will be masked. A summary of the data will be prepared for all subjects and categorized by the lens implanted. Variables measured on a continuous scale will be summarized to include sample size as well as the mean, standard deviation, median, minimum and maximum.
Time frame: 3 months post operatively
Binocular Uncorrected Distance Visual Acuity (UDVA) Measured at 4m.
Binocular UDVA measured at 4m. Visual acuity testing will be measured in LogMar and all study technicians and evaluators will be masked. A summary of the data will be prepared for all subjects and categorized by the lens implanted. Variables measured on a continuous scale will be summarized to include sample size as well as the mean, standard deviation, median, minimum and maximum.
Time frame: 3 months post operatively
Binocular Uncorrected Intermediate Visual Acuity (UIVA) Measured at 60cm.
Binocular UIVA measured at 60cm. Visual acuity testing will be measured in LogMar and all study technicians and evaluators will be masked. A summary of the data will be prepared for all subjects and categorized by the lens implanted. Variables measured on a continuous scale will be summarized to include sample size as well as the mean, standard deviation, median, minimum and maximum.
Time frame: 3 months post operatively
Binocular Uncorrected Near Visual Acuity (UNVA) Measured at 40cm.
Binocular UNVA measured at 40cm. Visual acuity testing will be measured in LogMar and all study technicians and evaluators will be masked. A summary of the data will be prepared for all subjects and categorized by the lens implanted. Variables measured on a continuous scale will be summarized to include sample size as well as the mean, standard deviation, median, minimum and maximum.
Time frame: 3 months post operatively
Binocular Target Corrected Defocus Curve
Binocular target corrected defocus curve. Visual acuity testing will be measured in LogMar and all study technicians and evaluators will be masked. A summary of the data will be prepared for all subjects and categorized by the lens implanted. Variables measured on a continuous scale will be summarized to include sample size as well as the mean, standard deviation, median, minimum and maximum.
Time frame: 3 months post operatively
Patient Reported Satisfaction by IOLSAT Questionnaire.
Patient reported satisfaction by IOLSAT questionnaire will be assessed. Variables measured on a categorical scale will be summarized to provide the number and percentage of subjects who provided each score. The percentage of patients "Satisfied" or "Very Satisfied" will be added for a total satisfaction percentage.
Time frame: 3 months post operatively
Patient Reported Dysphotopsias Questionnaire (QUVID).
Patient reported disphotopsias by QUVID questionnaire will be assessed. Variables measured on a categorical scale will be summarized to provide the number and percentage of subjects who provided each score. The percentage of subjects that answered "Never" for frequency are provided.
Time frame: 3 months post operatively
Post Operative Refraction, Manifest Refraction Spherical Equivalent (MRSE).
Post operative refraction. A summary of the data will be prepared for all subjects and categorized by the lens implanted. Variables measured on a continuous scale will be summarized to include sample size as well as the mean, standard deviation, median, minimum and maximum.
Time frame: 3 months post operatively
Spectacle Independence Utilizing the IOLSAT.
Spectacle independence utilizing the IOLSAT will be assessed. Variables measured on a categorical scale will be summarized to provide the number and percentage of subjects who provided each score. Spectacle independence was defined as answering "Never" or "Rarely" on the IOLSAT, the data presented is the percentage of subjects answering "Never" or "Rarely".
Time frame: 3 months post operatively
Binocular Distacne Corrected Near Visual Acuity (DCNVA) at 33cm.
Binocular DCNVA at 33cm. Visual acuity testing will be measured in LogMar and all study technicians and evaluators will be masked. A summary of the data will be prepared for all subjects and categorized by the lens implanted. Variables measured on a continuous scale will be summarized to include sample size as well as the mean, standard deviation, median, minimum and maximum.
Time frame: 3 months post operatively
| Milestone | Alcon PanOptix | Johnson & Johnson Synergy |
|---|---|---|
| Started | 153 | 77 |
| Completed | 153 | 77 |
| Not completed | 0 | 0 |
Binocular DCNVA Visual acuity testing will be measured in LogMar and all study technicians and evaluators will be masked. A summary of the data will be prepared for all subjects and categorized by the lens implanted. Variables measured on a continuous scale will be summarized to include sample size as well as the mean, standard deviation, median, minimum and maximum.
| logMAR | Alcon PanOptix | Johnson & Johnson Synergy |
|---|---|---|
| Binocular DCNVA (Distance Corrected Near Visual Acuity) at 40cm | 0.03 ± 0.08 | 0.01 ± 0.07 |
Binocular CDVA measured at 4m. Visual acuity testing will be measured in LogMar and all study technicians and evaluators will be masked. A summary of the data will be prepared for all subjects and categorized by the lens implanted. Variables measured on a continuous scale will be summarized to include sample size as well as the mean, standard deviation, median, minimum and maximum.
| logMAR | Alcon PanOptix | Johnson & Johnson Synergy |
|---|---|---|
| Binocular Corrected Distance Visual Acuity (CDVA) Measured at 4m. | -0.06 ± 0.06 | -0.07 ± 0.07 |
Binocular DCIVA measured at 60cm. Visual acuity testing will be measured in LogMar and all study technicians and evaluators will be masked. A summary of the data will be prepared for all subjects and categorized by the lens implanted. Variables measured on a continuous scale will be summarized to include sample size as well as the mean, standard deviation, median, minimum and maximum.
| logMAR | Alcon PanOptix | Johnson & Johnson Synergy |
|---|---|---|
| Binocular Distance Corrected Intermediate Visual Acuity (DCIVA) Measured at 60cm. | 0.00 ± 0.08 | 0.00 ± 0.07 |
Binocular UDVA measured at 4m. Visual acuity testing will be measured in LogMar and all study technicians and evaluators will be masked. A summary of the data will be prepared for all subjects and categorized by the lens implanted. Variables measured on a continuous scale will be summarized to include sample size as well as the mean, standard deviation, median, minimum and maximum.
| logMAR | Alcon PanOptix | Johnson & Johnson Synergy |
|---|---|---|
| Binocular Uncorrected Distance Visual Acuity (UDVA) Measured at 4m. | -0.01 ± 0.08 | 0.00 ± 0.08 |
Binocular UIVA measured at 60cm. Visual acuity testing will be measured in LogMar and all study technicians and evaluators will be masked. A summary of the data will be prepared for all subjects and categorized by the lens implanted. Variables measured on a continuous scale will be summarized to include sample size as well as the mean, standard deviation, median, minimum and maximum.
| logMAR | Alcon PanOptix | Johnson & Johnson Synergy |
|---|---|---|
| Binocular Uncorrected Intermediate Visual Acuity (UIVA) Measured at 60cm. | 0.00 ± 0.08 | 0.00 ± 0.08 |
Binocular UNVA measured at 40cm. Visual acuity testing will be measured in LogMar and all study technicians and evaluators will be masked. A summary of the data will be prepared for all subjects and categorized by the lens implanted. Variables measured on a continuous scale will be summarized to include sample size as well as the mean, standard deviation, median, minimum and maximum.
| logMAR | Alcon PanOptix | Johnson & Johnson Synergy |
|---|---|---|
| Binocular Uncorrected Near Visual Acuity (UNVA) Measured at 40cm. | 0.03 ± 0.08 | 0.03 ± 0.08 |
Binocular target corrected defocus curve. Visual acuity testing will be measured in LogMar and all study technicians and evaluators will be masked. A summary of the data will be prepared for all subjects and categorized by the lens implanted. Variables measured on a continuous scale will be summarized to include sample size as well as the mean, standard deviation, median, minimum and maximum.
| logMAR | Alcon PanOptix | Johnson & Johnson Synergy |
|---|---|---|
| -3.00 D | 0.12 ± 0.09 | 0.09 ± 0.09 |
| -2.50 D | 0.03 ± 0.08 | 0.03 ± 0.09 |
| -2.00 D | -0.01 ± 0.08 | 0.01 ± 0.09 |
| -1.50 D | 0.02 ± 0.09 | 0.02 ± 0.09 |
| -1.00 D | 0.10 ± 0.09 | 0.06 ± 0.09 |
| -0.50 D | 0.06 ± 0.07 | 0.03 ± 0.07 |
| -0.25 D | -0.02 ± 0.07 | -0.04 ± 0.06 |
| 0.00 D | -0.07 ± 0.07 | -0.06 ± 0.06 |
| 0.25 D | -0.03 ± 0.07 | -0.01 ± 0.08 |
| 0.50 D | 0.04 ± 0.07 | 0.04 ± 0.09 |
| 1.00 D | 0.22 ± 0.10 | 0.21 ± 0.11 |
Patient reported satisfaction by IOLSAT questionnaire will be assessed. Variables measured on a categorical scale will be summarized to provide the number and percentage of subjects who provided each score. The percentage of patients "Satisfied" or "Very Satisfied" will be added for a total satisfaction percentage.
| percentage of participants | Alcon PanOptix | Johnson & Johnson Synergy |
|---|---|---|
| Patient Reported Satisfaction by IOLSAT Questionnaire. | 89 | 94 |
Patient reported disphotopsias by QUVID questionnaire will be assessed. Variables measured on a categorical scale will be summarized to provide the number and percentage of subjects who provided each score. The percentage of subjects that answered "Never" for frequency are provided.
| percentage of participants | Alcon PanOptix | Johnson & Johnson Synergy |
|---|---|---|
| Starbursts | 65 | 49 |
| Halos | 38 | 38 |
| Glare | 48 | 55 |
| Haze | 84 | 86 |
| Blurred Vision | 87 | 75 |
| Double Vision | 97 | 100 |
| Dark Area | 98 | 96 |
Post operative refraction. A summary of the data will be prepared for all subjects and categorized by the lens implanted. Variables measured on a continuous scale will be summarized to include sample size as well as the mean, standard deviation, median, minimum and maximum.
| D | Alcon PanOptix | Johnson & Johnson Synergy |
|---|---|---|
| Post Operative Refraction, Manifest Refraction Spherical Equivalent (MRSE). | 0.24 ± 0.26 | 0.23 ± 0.26 |
Spectacle independence utilizing the IOLSAT will be assessed. Variables measured on a categorical scale will be summarized to provide the number and percentage of subjects who provided each score. Spectacle independence was defined as answering "Never" or "Rarely" on the IOLSAT, the data presented is the percentage of subjects answering "Never" or "Rarely".
| percentage of participants | Alcon PanOptix | Johnson & Johnson Synergy |
|---|---|---|
| Overall | 92 | 97 |
| Distance | 99 | 100 |
| Intermediate | 99 | 100 |
| Near | 93 | 96 |
Binocular DCNVA at 33cm. Visual acuity testing will be measured in LogMar and all study technicians and evaluators will be masked. A summary of the data will be prepared for all subjects and categorized by the lens implanted. Variables measured on a continuous scale will be summarized to include sample size as well as the mean, standard deviation, median, minimum and maximum.
| logMAR | Alcon PanOptix | Johnson & Johnson Synergy |
|---|---|---|
| Binocular Distacne Corrected Near Visual Acuity (DCNVA) at 33cm. | 0.09 ± 0.09 | 0.04 ± 0.08 |
Collected over 3 months postoperatively. Non-serious events are listed at a 0% frequency threshold.
| Group | Deaths | Serious | Other |
|---|---|---|---|
| Alcon PanOptix | 0/153 (0%) | 0/153 (0%) | 0/153 (0%) |
| Johnson & Johnson Synergy | 0/77 (0%) | 0/77 (0%) | 0/77 (0%) |
| Age, Continuous(years) | Alcon PanOptix | Johnson & Johnson Synergy | Total |
|---|---|---|---|
| Mean | 65.6 ± 8.3 | 65.9 ± 10.2 | 65.7 ± 9.0 |
| Sex: Female, Male(Participants) | Alcon PanOptix | Johnson & Johnson Synergy | Total |
|---|---|---|---|
| Female | 87 | 51 | 138 |
| Male | 66 | 26 | 92 |
| Race and Ethnicity Not Collected(Participants) | Alcon PanOptix | Johnson & Johnson Synergy | Total |
|---|---|---|---|
| Count of participants | — | — | 0 |
PDFs hosted by the registry, ClinicalTrials.gov.
Plan to share: No
Ran from Sep 2022 to primary completion in Apr 2024, 19 months.
Results were first posted in May 2025, 1 year 1 month after primary completion.
Of 16 observational studies under Pseudophakia, half reached primary completion within 10 months of starting (the median), counting those still running; a quarter within 4 and three quarters within 16. This study's 19 months is above that.
How these figures are worked out, and which studies are left out of them.
This study is completed, as verified in May 2025. You cannot join it, but the record below documents what was studied.
Get an email when the registry record changes — status, dates, results — or when someone posts here.
Sign in to followQuestions and observations about this study, from anyone following it. Not medical advice, and not a channel to the study team — their contact details are on the registry record.
Sign in to join the discussion. Reading takes no account; posting does. You choose a display name, and a pseudonym is the default.
Nothing here yet. If you are running this trial, taking part in it, or weighing whether to, this is the place to say so.
Berkeley Eye Center