ClinicalTrials.gg
CompletedNCT05602077SONOELBUpdated Apr 16, 2026

Accuracy of Sonography in Elbow Trauma

An interventional study of POCUS in Elbow Fracture, Radial Head Fracture and Elbow Sprain, sponsored by Eckehart SCHÖLL. Completed at 1 site in Switzerland. Open to participants aged 18 Years and older. Per ClinicalTrials.gov, last updated 2026-04-16.

Sponsored by Eckehart SCHÖLL · Not applicable, Interventional, and Diagnostic

How we know

Help build ClinicalTrials.gg — short surveys, remote interviews or testing, in your language. Take part →

Phase
Not applicable
Study type
Interventional
Enrollment
90
Allocation
Not applicable
Ages
18 Years and older
Sex
All
01

Study summary

X-rays (XR) are today the standard modality for the diagnosis of bone fractures in the lower or upper limbs in the emergency room. Point-of-care ultrasound (POCUS) is an alternative with some obvious advantages especially in the emergency room setting: It does not require the patient to fix the bone of interest in a stable position, allows observing the bone and joints under movement by the patient, can be performed at bedside, and avoids the exposure to radiation.

The advances in ultrasound technology has increased the interest in using POCUS as an alternative to XR in recent years. POCUS is used routinely prior to XR at the ORTHO-NOTFALL of the Merian Iselin Klinik Basel (MIK) in patients with suspicion for an indirect elbow trauma. It is the aim of this project to use this constellation in order to contribute to a systematic comparison of the value of the two modalities with the long-term aim to establish POCUS as the first-line diagnostic tool.

As a fist project, the SONOELB study was initiated. This study aims at a comparison of the diagnostic accuracy between XR and POCUS using CT as reference. The project started in October 2022 and aims at enrolling 130 patients until March 2025. The project is financially supported by the Merian Iselin Science Research PLC.

Read the detailed description

Objective:

The primary objective is to compare the diagnostic accuracy of POCUS and XR with respect to diagnosing fractures of the elbow after an indirect elbow trauma in the ED setting and to investigate the rate of agreement between the two modalities.

The primary outcome is the difference in diagnostic accuracy between the two modalities with respect to diagnosing a radial head fracture and the degree of agreement between the two modalities.

Secondary outcomes are the difference in diagnostic accuracy between the two modalities and the rate of agreement with respect to the other fracture types, to the decisions "any fracture", and to the decision "any fracture other than radial head".

Experimental Intervention (medical device) POCUS: The ultrasound examination of the injured elbow includes seven standard settings. The probe is placed on the joint in four ventral and in three posterior positions. If hemarthrosis is detected, this is always suspicious of a possible intra-articular fracture. Even the smallest amounts of blood can be detected sonographically.

The surfaces of the bones involved in the joint (humerus, ulna, radius) are accurately displayed in all seven sonography settings. Disrupted bone surface indicates a fracture.

POCUS will be performed according to the local SOP.

Control Intervention (standard/routine/comparator) XR: The conventional radiograph of the injured elbow consists of three standard views: ap, lateral and Norman oblique. This X-ray examination is the most commonly performed technique to date to diagnose an injured elbow.

CBCT (Cone Beam Computed Tomography): The injured elbow is placed in an almost most extended position in the CBCT tube. For this purpose, the affected arm is placed and fixed on a carbon-splint. The examination time is about 40 seconds XR will be performed according to the standard procedures of the ED of the MIK. The same holds for CBCT.

Any of the three diagnostic procedures applied can be discontinued in the case of patient discomfort, harm, or risk of harm according to the standard procedures of the MIK.

Compliance of the staff of the ED with performing the three modalities is supported by SOPs and internal training.

In the case of withdrawal of a patient, the reasons are recorded on the CRF. The data of these patients will not be included in the statistical analysis. The data will not be deleted in the data management system. Patients who withdraw themselves are offered a chat with the PI and further consultations.

Patients included in the trial will follow the standard management at the MIK. There are only two changes:

  • a CBCT is performed in addition after having performed both POCUS and XR, if there are no positive findings on POCUS or XR.
  • an additional blinded evaluation of all CBCTs will be done by one independent rater.

CBCT will be ordered by the staff of the ED in all patients and may be preliminary evaluated. However, these evaluations will not be documented as part of this study. They are also not accessible for the staff at the Radiology Department in the routine evaluation of the XRs.

02

Conditions studied

  • Elbow Fracture
  • Radial Head Fracture
  • Elbow Sprain
  • Coronoid Process Fracture
  • Distal Humerus Fracture

Browse trials for

Keywords

  • elbow
  • ultrasound
  • radial head
03

In context

Elbow Fractures

48 studies on the registry are indexed under Elbow Fractures; 14 are open to participants now.

This study's enrollment of 90 is above the median of 68 across 30 interventional studies indexed under Elbow Fractures.

Browse Elbow Fractures studies →

Lead sponsor

Eckehart SCHÖLL is the lead sponsor of 2 studies on the registry; none are open to participants now.

Counted across the registry records on this site, refreshed daily.

04

Who can participate

Ages eligible
18 Years and older
Sexes eligible
All
Accepts healthy volunteers
No

Go through the criteria one by one — yes, no or not sure — and take the list to your doctor or the study team. Kept in this browser only.

Inclusion criteria

  • signed by the subject
  • Suspicion for an indirect elbow trauma as part of the routine management at the ED of the MIK.

Exclusion criteria

Exclusion Criteria:

  • Age below 18
  • Patients who are lacking capacity of judgment
  • Patients with (temporary) cognitive impairment which makes an understanding of the patient information unlikely
  • Patients with limited knowledge of German or English which makes an understanding of the patient information unlikely
  • Patients with for US, XR or CT.
  • Lack of
Terms in these criteria, in plain language(2)

Underlined terms in the criteria open these too. Explained by clinicaltrials.gg, not part of the registry record. The study team decides who can take part.

Informed consent

Before you join, the study team explains what taking part involves — its purpose, what happens, the risks and possible benefits — and answers your questions, so you can decide freely. Consent is usually recorded on a form (the informed consent form, ICF) signed by you or, where the law allows, by someone legally authorized to decide for you.

You can keep asking questions during the study, you are told of new information that matters, and you can choose to leave at any time.

Contraindication

A reason a treatment, test or procedure should not be given to a particular person, such as an allergy, another illness or a medicine they take.

05

Study design

Phase
Not applicable
Primary purpose
Diagnostic
Allocation
Not applicable
Intervention model
Single group
Masking
None (open label)
Enrollment
90 participants (actual)

Study arms

  • Experimental
    POCUS and Control Intervention

    POCUS: Point of care ultrasound Control-Intervention: X-ray examination and Cone Beam Computed Tomography (CBCT)

    Device: POCUS

Interventions

  • DevicePOCUS

    POCUS: The ultrasound examination of the injured elbow includes seven standard settings. The probe is placed on the joint in four ventral and in three posterior positions. If hemarthrosis is detected, this is always suspicious of a possible intra-articular fracture. Even the smallest amounts of blood can be detected sonographically. The surfaces of the bones involved in the joint (humerus, ulna, radius) are accurately displayed in all seven sonography settings. Disrupted bone surface indicates a fracture. XR: The conventional radiograph of the injured elbow consists of three standard views: ap, lateral and Norman oblique. CBCT: The injured elbow is placed in an almost most extended position in the CBCT tube.

    Also known as: Control Intervention: XR / CBCT

06

What researchers measure

Primary outcomes

  1. Difference in diagnostic accuracy of sonography in radial head fractures compared with plain x-ray

    In order to assess the diagnostic accuracy, CBCT is used as a reference standard in all patients. The findings from the POCUS, XR, and CBCT with respect to a fracture of the radial head are documented on three different CRFs: POCUS, XR, CBCT. CRF POCUS (7 views): unaffected(Y/N) - haemarthros (y/n) - fractures of the different parts CRF XR: (ap/lateral/Norman): unaffected(Y/N) - fat pad sign (y/n) - fractures of the different parts CRF CBCT: unaffected(Y/N) - fractures of the different parts

    Time frame: within the emergency department stay (1 day)

Secondary outcomes

  1. Difference in diagnostic accuracy of sonography in other elbow fractures compared with plain x-ray: Fossa olecrani

    difference in diagnostic accuracy between the two modalities and the rate of agreement with respect to the other fracture types, to the decisions "any fracture", and to the decision "any fracture other than radial head". Fossa olecrani fractures as part of the distal humerus CRF POCUS (7 views): unaffected(Y/N) - haemarthros (y/n) - fractures of the different parts CRF XR: (ap/lateral/Norman): unaffected(Y/N) - fat pad sign (y/n) - fractures of the different parts CRF CBCT: unaffected(Y/N) - fractures of the different parts

    Time frame: within the emergency department stay (1 day)

  2. Difference in diagnostic accuracy of sonography in other elbow fractures compared with plain x-ray: supracondylar fracture

    difference in diagnostic accuracy between the two modalities and the rate of agreement with respect to the other fracture types, to the decisions "any fracture", and to the decision "any fracture other than radial head". Supracondylar fractures as part of the distal humerus CRF POCUS (7 views): unaffected(Y/N) - haemarthros (y/n) - fractures of the different parts CRF XR: (ap/lateral/Norman): unaffected(Y/N) - fat pad sign (y/n) - fractures of the different parts CRF CBCT: unaffected(Y/N) - fractures of the different parts

    Time frame: within the emergency department stay (1 day)

  3. Difference in diagnostic accuracy of sonography in other elbow fractures compared with plain x-ray: condylar fracture

    difference in diagnostic accuracy between the two modalities and the rate of agreement with respect to the other fracture types, to the decisions "any fracture", and to the decision "any fracture other than radial head". medial or lateral fractures as part of the distal humerus CRF POCUS (7 views): unaffected(Y/N) - haemarthros (y/n) - fractures of the different parts CRF XR: (ap/lateral/Norman): unaffected(Y/N) - fat pad sign (y/n) - fractures of the different parts CRF CBCT: unaffected(Y/N) - fractures of the different parts

    Time frame: within the emergency department stay (1 day)

  4. Difference in diagnostic accuracy of sonography in other elbow fractures compared with plain x-ray: capitulum humeri fracture

    difference in diagnostic accuracy between the two modalities and the rate of agreement with respect to the other fracture types, to the decisions "any fracture", and to the decision "any fracture other than radial head". capitulum humeri fracture as part of the distal humerus CRF POCUS (7 views): unaffected(Y/N) - haemarthros (y/n) - fractures of the different parts CRF XR: (ap/lateral/Norman): unaffected(Y/N) - fat pad sign (y/n) - fractures of the different parts CRF CBCT: unaffected(Y/N) - fractures of the different parts

    Time frame: within the emergency department stay (1 day)

  5. Difference in diagnostic accuracy of sonography in other elbow fractures compared with plain x-ray: Coronoid process fracture

    difference in diagnostic accuracy between the two modalities and the rate of agreement with respect to the other fracture types, to the decisions "any fracture", and to the decision "any fracture other than radial head". Coronoid process fracture as part of the proximal ulna CRF POCUS (7 views): unaffected(Y/N) - haemarthros (y/n) - fractures of the different parts CRF XR: (ap/lateral/Norman): unaffected(Y/N) - fat pad sign (y/n) - fractures of the different parts CRF CBCT: unaffected(Y/N) - fractures of the different parts

    Time frame: within the emergency department stay (1 day)

  6. Difference in diagnostic accuracy of sonography in other elbow fractures compared with plain x-ray: Olecranon fracture

    difference in diagnostic accuracy between the two modalities and the rate of agreement with respect to the other fracture types, to the decisions "any fracture", and to the decision "any fracture other than radial head". Olecranon fracture as part of the proximal ulna CRF POCUS (7 views): unaffected(Y/N) - haemarthros (y/n) - fractures of the different parts CRF XR: (ap/lateral/Norman): unaffected(Y/N) - fat pad sign (y/n) - fractures of the different parts CRF CBCT: unaffected(Y/N) - fractures of the different parts

    Time frame: within the emergency department stay (1 day)

07

Study locations

1 site
  • Merian Iselin Klinik
    Basel, 4009, Switzerland
08

References and documents

Publications

  • Tsou PY, Ma YK, Wang YH, Gillon JT, Rafael J, Deanehan JK. Diagnostic accuracy of ultrasound for upper extremity fractures in children: A systematic review and meta-analysis. Am J Emerg Med. 2021 Jun;44:383-394. doi: 10.1016/j.ajem.2020.04.071. Epub 2020 Apr 27. PubMed 32507477 ↗
  • Pourmand A, Shokoohi H, Maracheril R. Diagnostic accuracy of point-of-care ultrasound in detecting upper and lower extremity fractures: An evidence-based approach. Am J Emerg Med. 2018 Jan;36(1):134-136. doi: 10.1016/j.ajem.2017.06.052. Epub 2017 Jun 27. No abstract available. PubMed 28669695 ↗
  • Champagne N, Eadie L, Regan L, Wilson P. The effectiveness of ultrasound in the detection of fractures in adults with suspected upper or lower limb injury: a systematic review and subgroup meta-analysis. BMC Emerg Med. 2019 Jan 28;19(1):17. doi: 10.1186/s12873-019-0226-5. PubMed 30691395 ↗
  • Hanlon DP, Mavrophilipos V. The Emergent Evaluation and Treatment of Elbow and Forearm Injuries. Emerg Med Clin North Am. 2020 Feb;38(1):81-102. doi: 10.1016/j.emc.2019.09.005. PubMed 31757256 ↗
  • Bianchi S. Ultrasound and bone: a pictorial review. J Ultrasound. 2020 Sep;23(3):227-257. doi: 10.1007/s40477-020-00477-4. Epub 2020 May 17. PubMed 32419074 ↗
  • De Maeseneer M, Jacobson JA, Jaovisidha S, Lenchik L, Ryu KN, Trudell DR, Resnick D. Elbow effusions: distribution of joint fluid with flexion and extension and imaging implications. Invest Radiol. 1998 Feb;33(2):117-25. doi: 10.1097/00004424-199802000-00010. PubMed 9493728 ↗
  • Rutten MJ, Collins JM, de Waal Malefijt MC, Kiemeney LA, Jager GJ. Unsuspected sonographic findings in patients with posttraumatic shoulder complaints. J Clin Ultrasound. 2010 Nov-Dec;38(9):457-65. doi: 10.1002/jcu.20745. PubMed 20848574 ↗
  • Malahias MA, Manolopoulos PP, Kadu V, Shahpari O, Fagkrezos D, Kaseta MK. Bedside Ultrasonography for Early Diagnosis of Occult Radial Head Fractures in Emergency Room: A CT-Comparative Diagnostic Study. Arch Bone Jt Surg. 2018 Nov;6(6):539-546. PubMed 30637310 ↗
  • Avci M, Kozaci N, Beydilli I, Yilmaz F, Eden AO, Turhan S. The comparison of bedside point-of-care ultrasound and computed tomography in elbow injuries. Am J Emerg Med. 2016 Nov;34(11):2186-2190. doi: 10.1016/j.ajem.2016.08.054. Epub 2016 Aug 27. PubMed 27645809 ↗
  • Waterbrook AL, Adhikari S, Stolz U, Adrion C. The accuracy of point-of-care ultrasound to diagnose long bone fractures in the ED. Am J Emerg Med. 2013 Sep;31(9):1352-6. doi: 10.1016/j.ajem.2013.06.006. Epub 2013 Jul 26. PubMed 23891601 ↗
  • Avci M, Kozaci N, Tulubas G, Caliskan G, Yuksel A, Karaca A, Doganay F, Etli I. Comparison of Point-of-Care Ultrasonography and Radiography in the Diagnosis of Long-Bone Fractures. Medicina (Kaunas). 2019 Jul 9;55(7):355. doi: 10.3390/medicina55070355. PubMed 31324028 ↗
  • Eckert M, Vach W. On the use of comparison regions in visualizing stochastic uncertainty in some two-parameter estimation problems. Biom J. 2020 May;62(3):598-609. doi: 10.1002/bimj.201800232. Epub 2019 Oct 29. PubMed 31661558 ↗

Individual participant data

Plan to share: No

09

Timeline

Tracking since Sep 25, 2026
ElapsedEstimatedEstimated, not yet reachedSimilar studies: half by the dot; the band is the middle halfHalf of similar studies reached it by the dot; the band is the middle half, from a quarter to three quarters

Ran from Nov 2022 to primary completion in Mar 2025, 28 months.

Of 16 interventional studies with no phase under Elbow Fractures, half reached primary completion within 22 months of starting (the median), counting those still running; a quarter within 12 and three quarters within 36. This study's 28 months is above that.

How these figures are worked out, and which studies are left out of them.

Registered
Oct 22, 2022
First posted
Nov 1, 2022
StartActual
Nov 1, 2022
Primary completionActual
Mar 31, 2025
CompletionActual
Mar 31, 2025
Last update
Apr 16, 2026
What these dates mean
Start.
When the first participant enrolled; while estimated, when the study expects to open to recruitment.
Primary completion.
When the last participant was examined or treated to collect data for the study's main question, its primary outcome. A study that stopped early gives the date its data collection stopped.
Completion.
When the last participant's last visit took place, for every outcome, secondary ones and side effects included: the end of the study. Often later than primary completion, sometimes the same day.
Actual and Est.
Actual means the registry says the date has happened. Est. (estimated) is a date the sponsor plans or expects. It can still move, and the sponsor is expected to change it to actual once it has passed.
No changes since tracking began. The registry record was last updated on Apr 16, 2026, before this site started recording changes on Sep 25, 2026. Its history is on ClinicalTrials.gov ↗
10

Registry details

Key details

Study ID
NCT05602077
Lead sponsor
Eckehart SCHÖLL
Collaborators
Basel Academy for Quality and Research in Medicine, Merian Iselin Klinik; Anja Mair (medical specialist), Merian Iselin Klinik; Dr. Thomas Egelhof (head of radiology)
Responsible party
Eckehart SCHÖLL (Head of Emergency Department, Merian Iselin Klinik) — Sponsor-investigator
First posted
Nov 1, 2022
Start date
Nov 1, 2022
Primary completion
Mar 31, 2025
Completion
Mar 31, 2025
Last update
Apr 16, 2026

Oversight

FDA-regulated drug
No
FDA-regulated device
No
View the source record on ClinicalTrials.gov ↗

Not currently enrolling

This study is completed, as verified in Mar 2025. You cannot join it, but the record below documents what was studied.

Follow this study

Get an email when the registry record changes — status, dates, results — or when someone posts here.

Sign in to follow

Discussion

Questions and observations about this study, from anyone following it. Not medical advice, and not a channel to the study team — their contact details are on the registry record.

Sign in to join the discussion. Reading takes no account; posting does. You choose a display name, and a pseudonym is the default.

Nothing here yet. If you are running this trial, taking part in it, or weighing whether to, this is the place to say so.

Start the discussion