ClinicalTrials.gg
CompletedNCT04953390Updated Nov 9, 2022Results posted

Evaluating Benefits of Hearing Aid Microphone Directionality Technologies

An interventional study of Phonak Audeo hearing aid and Phonak hearing aid with multiple directionality settings, adjustable via a mobile app in Hearing Loss, sponsored by Sonova AG. Completed at 1 site in United States. Open to participants aged 18 Years to 90 Years. Per ClinicalTrials.gov, last updated 2022-11-09.

Sponsored by Sonova AG · Not applicable, Interventional, and Treatment

Phase
Not applicable
Study type
Interventional
Enrollment
19
Allocation
Not applicable
Ages
18 Years to 90 Years
Sex
All
01

Study summary

This study will evaluate the impact of hearing aid microphone directionality technologies and settings on speech understanding in noise for experienced hearing aid users. It will also evaluate the participant's spatial awareness of sounds using these different hearing aid microphone directionality technologies.

02

Conditions studied

  • Hearing Loss

Browse trials for

03

In context

Hearing Loss

1,109 studies on the registry are indexed under Hearing Loss; 233 are open to participants now.

This study's enrollment of 19 is below the median of 40 across 778 interventional studies indexed under Hearing Loss.

Browse Hearing Loss studies →

Lead sponsor

Sonova AG is the lead sponsor of 88 studies on the registry; 6 are open to participants now.

Of its 27 completed or terminated interventional studies of FDA-regulated products, 19 (70%) have results posted.

Counted across the registry records on this site, refreshed daily.

04

Who can participate

Ages eligible
18 Years to 90 Years
Sexes eligible
All
Accepts healthy volunteers
No

Go through the criteria one by one — yes, no or not sure — and take the list to your doctor or the study team. Kept in this browser only.

Inclusion criteria

  • 18 years or older
  • experienced hearing aid users
  • moderate to moderate severe sensorineural symmetrical hearing loss defined as a difference of less than 10 dB between ears
  • must be able to use app and smart phone

Exclusion criteria

Exclusion Criteria:

  • asymmetrical hearing losses
  • unable or unwilling to use app and smart phone
05

Study design

Phase
Not applicable
Primary purpose
Treatment
Allocation
Not applicable
Intervention model
Single group
Masking
None (open label)
Enrollment
19 participants (actual)

Study arms

  • Experimental
    Experimental

    All study participants wearing study devices and evaluating three different microphone settings in simulated noise environments in lab, and using study devices during home trial period.

    Device: Phonak Audeo hearing aid · Device: Phonak hearing aid with multiple directionality settings, adjustable via a mobile app

Interventions

  • DevicePhonak Audeo hearing aid

    Commercially available hearing aid with three different microphone settings: DIR1, DIR2, and DIR3

  • DevicePhonak hearing aid with multiple directionality settings, adjustable via a mobile app

    Commercially available hearing aid with multiple directionality settings which will be adjustable by user via a mobile app during a home trial period.

06

What researchers measure

Primary outcomes

  1. Subjective Description of DIR1, DIR2, and DIR3 in Controlled Soft Noise Environment

    Participant describes an acoustically noisy environment in which recorded speech is played from a speaker directly in front of the participant and recorded multi-talker babble is played from multiple speakers around the participant. The participant uses a slider tool to choose if scene sounds acoustically wide (hearing all noise and speech), or acoustically narrow (hearing more of the speech than the noise). The range of the slider is 0-100, with 0 indicating the sound scene is "wide" and 100 indicating the sound scene is "narrow". The slider moves in 5 point increments. This is a purely subjective description and there is no better or worse outcome.

    Time frame: Third appointment (day 28 of study)

  2. Subjective Description of DIR1, DIR2, and DIR3 in Controlled Loud Noise Environment

    Participant describes an acoustically noisy environment in which recorded speech is played from a speaker directly in front of the participant and recorded multi-talker babble is played from multiple speakers around the participant. The participant uses a slider tool to choose if scene sounds acoustically wide (hearing all noise and speech), or acoustically narrow (hearing more of the speech than the noise). The range of the slider is 0-100, with 0 indicating the sound scene is "wide" and 100 indicating the sound scene is "narrow". The slider moves in 5 point increments. This is a purely subjective description and there is no better or worse outcome.

    Time frame: Third appointment (day 28 of study)

  3. Subjective Preference DIR1, DIR2, and DIR3 in Controlled Soft Noise Environments

    Using a sliding scale, the participant chooses their preference for listening to the sound scene, however this time, 0 indicates "not preferred" and 100 indicates "most preferred". The slider moves in 5 point increments. This is purely subjective and there is no better or worse answer.

    Time frame: Third appointment (day 28 of study)

  4. Subjective Preference DIR1, DIR2, and DIR3 in Controlled Loud Noise Environments

    Using a sliding scale, the participant chooses their preference for listening to the sound scene, however this time, 0 indicates "not preferred" and 100 indicates "most preferred". The slider moves in 5 point increments.

    Time frame: Third appointment (day 28 of study)

Secondary outcomes

  1. Speech Reception Threshold

    Objective measure of speech reception thresholds with all three microphone settings (DIR1,DIR2,DIR3). This is calculated as the Signal to Noise Ratio at which participant can correctly repeat 50% of the words. A negative number (i.e. -10) indicates that the participant correctly repeated 50% of the words when the speech signal was softer or lower than the noise level. For example, an SNR score of -10 means that the the participant correctly repeated 50% of the words when the speech signal was 10 dB softer than the noise level. In this case, the noise level was appropriate to the microphone setting, i.e., DIR1 was tested in softer noise and DIR2 and DIR3 were tested in loud noise.

    Time frame: 2nd appointment (Day 14 of study)

  2. Observations and Ratings of Satisfaction of Microphone Directionality in Real Life

    Participants made adjustments of microphone directionality via an app, in real world listening situations. When participants adjusted the microphone directionality in real-time, they were also prompted via ecological momentary assessment to rate how satisfied they were with the adjustment. Participants chose one of three satisfaction ratings: no, slight, or clear. "Clear" satisfaction would be the best rating, indicating high satisfaction, "no" would be the worst rating, indicating no satisfaction, and "slight" would indicate somewhat satisfied.

    Time frame: 4 weeks

  3. Subjective Ratings of Transition Speed From One Directional Microphone Setting to Another Directional Setting

    Participants listen to different samples of transition speed from one mic setting to another in an A/B comparison and rate which sample is more noticeable, i.e. A is more noticeable than B, A is less noticeable than B, or A and B are the same. No statistical analysis was done for this outcome measure. Frequency distribution was completed to record the number of responses in which participants rated a 0 second transition time more noticeable than a 2s, 4s, and 8s transition time.

    Time frame: Third appointment (day 28 of study)

07

Results

Posted Nov 9, 2022

Participant flow

Participant flow — Overall Study
MilestoneExperimental
Started19
Completed19
Not completed0

Outcome measures

PrimarySubjective Description of DIR1, DIR2, and DIR3 in Controlled Soft Noise Environment

Participant describes an acoustically noisy environment in which recorded speech is played from a speaker directly in front of the participant and recorded multi-talker babble is played from multiple speakers around the participant. The participant uses a slider tool to choose if scene sounds acoustically wide (hearing all noise and speech), or acoustically narrow (hearing more of the speech than the noise). The range of the slider is 0-100, with 0 indicating the sound scene is "wide" and 100 indicating the sound scene is "narrow". The slider moves in 5 point increments. This is a purely subjective description and there is no better or worse outcome.

Time frame:
Third appointment (day 28 of study)
Reported as:
Mean · units on a scale
Subjective Description of DIR1, DIR2, and DIR3 in Controlled Soft Noise Environment
units on a scaleExperimental
Perceived narrowness of DIR1 in soft noise40.31 ± 24.73
Perceived narrowness DIR2 in soft noise55.94 ± 19.99
Perceived narrowness DIR3 in soft noise66.88 ± 18.81
Statistical analysis
  • Experimental · ANOVA · p = 0.004
PrimarySubjective Description of DIR1, DIR2, and DIR3 in Controlled Loud Noise Environment

Participant describes an acoustically noisy environment in which recorded speech is played from a speaker directly in front of the participant and recorded multi-talker babble is played from multiple speakers around the participant. The participant uses a slider tool to choose if scene sounds acoustically wide (hearing all noise and speech), or acoustically narrow (hearing more of the speech than the noise). The range of the slider is 0-100, with 0 indicating the sound scene is "wide" and 100 indicating the sound scene is "narrow". The slider moves in 5 point increments. This is a purely subjective description and there is no better or worse outcome.

Time frame:
Third appointment (day 28 of study)
Reported as:
Mean · units on a scale
Subjective Description of DIR1, DIR2, and DIR3 in Controlled Loud Noise Environment
units on a scaleExperimental
Perceived narrowness DIR1 in loud noise35.31 ± 26.23
Perceived narrowness DIR2 in loud noise48.91 ± 22.71
Perceived narrowness DIR3 in loud noise57.5 ± 19.26
Statistical analysis
  • Experimental · ANOVA · p = .029
PrimarySubjective Preference DIR1, DIR2, and DIR3 in Controlled Soft Noise Environments

Using a sliding scale, the participant chooses their preference for listening to the sound scene, however this time, 0 indicates "not preferred" and 100 indicates "most preferred". The slider moves in 5 point increments. This is purely subjective and there is no better or worse answer.

Time frame:
Third appointment (day 28 of study)
Reported as:
Mean · units on a scale
Subjective Preference DIR1, DIR2, and DIR3 in Controlled Soft Noise Environments
units on a scaleExperimental
Preference for DIR1 in soft noise31.41 ± 24.22
Preference for DIR2 in soft noise53.13 ± 21.03
Preference for DIR3 in soft noise64.1 ± 16.28
Statistical analysis
  • Experimental · ANOVA · p = 0.0002
SecondarySpeech Reception Threshold

Objective measure of speech reception thresholds with all three microphone settings (DIR1,DIR2,DIR3). This is calculated as the Signal to Noise Ratio at which participant can correctly repeat 50% of the words. A negative number (i.e. -10) indicates that the participant correctly repeated 50% of the words when the speech signal was softer or lower than the noise level. For example, an SNR score of -10 means that the the participant correctly repeated 50% of the words when the speech signal was 10 dB softer than the noise level. In this case, the noise level was appropriate to the microphone setting, i.e., DIR1 was tested in softer noise and DIR2 and DIR3 were tested in loud noise.

Time frame:
2nd appointment (Day 14 of study)
Reported as:
Mean · dB SNR
Speech Reception Threshold
dB SNRExperimental
SNR level for DIR1 in soft noise-10.22 ± 2.4
SNR level for DIR2 in loud noise-12.35 ± 1.75
SNR level for DIR3 in loud noise-11.85 ± 1.94
Statistical analysis
  • Experimental · t-test, 2 sided · p = .14T-test done on DIR2 and DIR3 results only, as the conditions were equal for these two settings. DIR1 was tested in a different condition.
SecondaryObservations and Ratings of Satisfaction of Microphone Directionality in Real Life

Participants made adjustments of microphone directionality via an app, in real world listening situations. When participants adjusted the microphone directionality in real-time, they were also prompted via ecological momentary assessment to rate how satisfied they were with the adjustment. Participants chose one of three satisfaction ratings: no, slight, or clear. "Clear" satisfaction would be the best rating, indicating high satisfaction, "no" would be the worst rating, indicating no satisfaction, and "slight" would indicate somewhat satisfied.

Time frame:
4 weeks
Reported as:
Number · adjustments
Observations and Ratings of Satisfaction of Microphone Directionality in Real Life
adjustmentsExperimental
Number of adjustments in which user rated "clear" satisfaction113
Number of adjustments in which users rated "slight" satisfaction95
Number of adjustments in which user rated "no" satisfaction47
SecondarySubjective Ratings of Transition Speed From One Directional Microphone Setting to Another Directional Setting

Participants listen to different samples of transition speed from one mic setting to another in an A/B comparison and rate which sample is more noticeable, i.e. A is more noticeable than B, A is less noticeable than B, or A and B are the same. No statistical analysis was done for this outcome measure. Frequency distribution was completed to record the number of responses in which participants rated a 0 second transition time more noticeable than a 2s, 4s, and 8s transition time.

Time frame:
Third appointment (day 28 of study)
Reported as:
Number · comparisons between two time constants
Subjective Ratings of Transition Speed From One Directional Microphone Setting to Another Directional Setting
comparisons between two time constantsExperimental
Number of times 0 seconds is rated as more noticeable than 2,4,or 8 seconds58
Number of times 0 seconds is rated as no different than 2,4, or 8 seconds29
Number of times 0 seconds is rated as less noticeable than 2,4, or 8 seconds27
PrimarySubjective Preference DIR1, DIR2, and DIR3 in Controlled Loud Noise Environments

Using a sliding scale, the participant chooses their preference for listening to the sound scene, however this time, 0 indicates "not preferred" and 100 indicates "most preferred". The slider moves in 5 point increments.

Time frame:
Third appointment (day 28 of study)
Reported as:
Mean · units on a scale
Subjective Preference DIR1, DIR2, and DIR3 in Controlled Loud Noise Environments
units on a scaleExperimental
Preference for DIR1 in loud noise26.25 ± 26
Preference for DIR2 in loud noise43.75 ± 20.43
Preference for DIR3 in loud noise60.78 ± 19.81
Statistical analysis
  • Experimental · ANOVA · p = .0003

Adverse events

Collected over 4-6 weeks. Non-serious events are listed at a 0% frequency threshold.

Adverse event summary by group
GroupDeathsSeriousOther
Experimental0/19 (0%)0/19 (0%)0/19 (0%)

Baseline characteristics

All participants who were tested using different microphone directionality settings.

Age, Continuous
Age, Continuous(years)Experimental
Mean72 (39 to 88)
Sex: Female, Male
Sex: Female, Male(Participants)Experimental
Female10
Male9
Race and Ethnicity Not Collected
Race and Ethnicity Not Collected(Participants)Experimental
Region of Enrollment
Region of Enrollment(participants)Experimental
United States19
Hearing Loss
Hearing Loss(Participants)Experimental
Count of participants19
08

Study locations

1 site
  • Sonova
    Aurora, Illinois 60505, United States
09

References and documents

Study documents

  • Protocol and statistical analysis plan · May 24, 2022

Documents are hosted by the registry — open the source record to download them.

Individual participant data

Plan to share: No

10

Updates

Tracking since Sep 25, 2026
No changes since tracking began. The registry record was last updated on Nov 9, 2022, before this site started recording changes on Sep 25, 2026. Its history is on ClinicalTrials.gov ↗
11

Registry details

Key details

Study ID
NCT04953390
Lead sponsor
Sonova AG
Responsible party
Sponsor
First posted
Jul 8, 2021
Start date
May 3, 2021
Primary completion
Jul 2, 2021
Completion
Jul 2, 2021
Results posted
Nov 9, 2022
Last update
Nov 9, 2022

Study contacts

Kevin Seitz-Paquette, AuD
principal investigator · Sonova AG

Oversight

FDA-regulated drug
No
FDA-regulated device
Yes
View the source record on ClinicalTrials.gov ↗

Not currently enrolling

This study is completed, as verified in Jul 2021. You cannot join it, but the record below documents what was studied.

Follow this study

Get an email when the registry record changes — status, dates, results — or when someone posts here.

Sign in to follow

Discussion

Questions and observations about this study, from anyone following it. Not medical advice, and not a channel to the study team — their contact details are on the registry record.

Sign in to join the discussion. Reading takes no account; posting does. You choose a display name, and a pseudonym is the default.

Nothing here yet. If you are running this trial, taking part in it, or weighing whether to, this is the place to say so.

Start the discussion