ClinicalTrials.gg
RecruitingNCT04678258ZERO MAGICUpdated Jun 15, 2026

Zero Fluoroscopy Voltage Guided vs. Linear CTI Ablation

An interventional study of HR electroanatomic mapping and MVG catheter ablation and Conventional bipolar mapping and linear catheter ablation in Catheter Ablation, Atrial Flutter Typical and Radiation Exposure, sponsored by Klinikum-Fuerth. Recruiting at 1 site in Germany. Open to participants aged 18 Years and older. Per ClinicalTrials.gov, last updated 2026-06-15.

Sponsored by Klinikum-Fuerth · Not applicable, Interventional, and Treatment

How we know

From the registry’s dates

  • Started Nov 2020; still recruiting 5 years 11 months later.

Help build ClinicalTrials.gg — short surveys, remote interviews or testing, in your language. Take part →

Phase
Not applicable
Study type
Interventional
Enrollment
106
Allocation
Randomized
Ages
18 Years and older
Sex
All
01

Where this study stands

Counted across the records on this site · 2026-11-23

Among 31 studies in Atrial Flutter with a site in Germany — 5 open to participants now, 7 under way, none of them phase 3. Atrial Flutter · Germany.

Planned enrollment
14th of 24
106 · median 160
Started
2020
with 1 other
No phase
12 of 31
2 open now
Registered
24th of 31
by date

Among the 31 studies in Atrial Flutter with a site in Germany, this one is the 14th largest by planned enrollment of the 24 interventional ones that give a count, is one of 2 that started in 2020, is one of 12 with no phase, and was the 24th registered.

Atrial Flutter

223 studies on the registry are indexed under Atrial Flutter; 51 are open to participants now.

Browse Atrial Flutter studies →

Open to participants now

5 of the 31 studies in Atrial Flutter with a site in Germany are open now. Recruiting first, the newest first:

All 5 open studies →

A study can be open while its sites in Germany have not opened yet or have stopped. Only those recruiting at a site in Germany →

Who these studies take

Of the 35 Atrial Flutter studies recruiting now, 29 (83%) set no upper age limit and none (0%) stop at 75 or younger; 1 takes children under 18; 4 take healthy volunteers.

This study: 18 Years and older · all sexes · no healthy volunteers.

The full table on the hub →

This tab as a report to print or save as PDF → With an account.

Was this useful?
Get alerts for this landscapeDownload CSVNarrow it in search →With an account: a weekly mail of what changed among 31 studies in Atrial Flutter with a site in Germany, or all of them as a file.
02

Study summary

Catheter ablation of the cavo-tricuspid isthmus (CTI) is the curative first-line therapy for typical atrial flutter. Currently, two approaches are used in clinical practice. In contrast to the conventional linear ablation approach, the Maximum voltage-guided (MVG) strategy aims to limit ablation to high voltage areas (HVAs) representing the detectable correlate of relevant conducting bundles. Data from registries show that the MVG technique is sufficient to reach comparable clinical outcome with significantly shorter ablation duration when compared to the conventional linear strategy.

Despite growing evidence, however, data from properly powered prospective randomized trials are lacking and the linear approach still remains standard. In addition, data on radiation exposure are controversial.

As a substrate-based approach, the MVG strategy requires detailed mapping and signal analysis for identification of the individual architecture and exactly targeted energy application. However, the spatial mapping resolution of large tip catheters is limited. The use of the MicroFidelity catheter technology (IntellaMiFi) with high resolution mini-electrodes at the 8 mm catheter tip can be expected to further improve the feasibility of a voltage-guided approach. In addition, the MVG approach theoretically may encompass an increased risk for clinically inapparent reconduction. A prospective study with predefined invasive re-evaluation of persistent CTI block is needed to further evaluate this issue.

Objective of this prospective randomized study is evaluate the performance of the micro-sensor technology for zero-fluoroscopy voltage-guided ablation of typical atrial flutter (AFL) compared with a population undergoing conventional linear ablation including a predefined invasive re-evaluation of persistent CTI block in addition to clinical follow-up.

The study has been approved by the responsible ethics committee.

Read the detailed description

Rationale:

Catheter ablation of the CTI represents the established curative first-line treatment for typical AFl. Although the acute and chronic efficacy is high, conventional ablation is still time consuming, requires a considerable amount of radiation as reported even in the most recent trials and treatment failure occurs.

The MVG catheter ablation of the CTI aims to limit energy delivery by selectively treating conductive bundles. Compared to the conventional linear strategy, a reduction of ablation and procedural time had been shown for the MVG technique. For several reasons, however, the current evidence is still not considered to be robust enough to suggest a general change in the ablation approach:

  • Despite a reduction in ablation requirements, the additional time needed for voltage mapping often prolongs the total procedure duration.
  • The spatial mapping resolution of large tip catheters, most often used for CTI-ablation is limited.
  • Catheter positioning and CTI ablation is still guided by fluoroscopy with the well-known potential harm in the majority of electrophysiological centers. There are conflicting data for the MVG approach regarding radiation duration.
  • The MVG approach theoretically encompasses an increased risk for clinically inapparent reconduction. A prospective study with predefined invasive re-evaluation of persistent CTI block is lacking.

Aims of the study:

MicroFidelity catheter technology was introduced to enhance the spatial resolution of large tip catheters and may facilitate zero-fluoroscopy substrate-guided ablation by high-resolution (HR) electroanatomic mapping (EAM) and precisely targeted energy application.

This study is designed to prospectively evaluate safety and efficacy of the stepwise maximum voltage mapping guided CTI ablation strategy ("MVG") using IntellaMiFi technology compared with a randomized cohort undergoing conventional linear CTI ablation (control).

Beyond procedural efficacy (main hypothesis) and safety patients outcome will be evaluated

  1. by electrophysiologic diagnostic reevaluation of the ablation success after 3 months,
  2. by clinical assessment and Holter-monitoring during 6 and 12-month follow-up. Furthermore, we aim to validate efficacy and safety of three-dimensional EAM- guided CTI ablation without the use of fluoroscopy as standard approach in clinical routine.

The prospective randomized analysis aims to provide fundamental data to suggest a general change in the CTI ablation approach towards a three-dimensional electroanatomical mapping guided, substrate-orientated stepwise procedure without the use of radiation as clinical standard (Zero MAGIC).

Study design and hypothesis:

Single center, prospective randomized trial, two arms ("MVG": voltage mapping guided CTI ablation versus "control" undergoing linear approach), patients blinded to the treatment.

Investigators that perform follow-up will be blinded regarding the patients group.

The study is designed to prospectively compare two different ablation strategies for the curative treatment of documented typical (CTI dependent) atrial flutter regarding efficacy and safety. Patients will be randomized either to undergo a voltage mapping guided CTI ablation or to a second group ablated using the conventional linear approach in order to investigate the following hypotheses:

Main hypothesis The zero-fluoroscopy MVG ablation approach significantly reduces CTI-ablation duration (total radiofrequency (RF) energy (RFE) application time) to bidirectional conduction block (BCB) compared with the conventional linear strategy.

Further hypotheses

  • Over 90% of all procedures (MVG and conventional linear) can be safely performed without the use of radiation, cardiac implantable electronic devices (CIEDs) excluded.
  • IntellaMiFi electrodes localize the higher voltage potentials with higher accuracy compared to conventional bipoles.
  • There is no difference in the occurrence of complications, such as tamponade, atrio-ventricular (AV) block, charring of catheter tip and sedation side effects.
  • There is no difference in the rate of persistent BCB in electrophysiologic re-evaluation after 3 months.
  • There is no difference in the recurrence rate of typical atrial flutter as estimated by 6 and 12 month clinical and Holter electrocardiogram follow-up.

Patients:

The trial will include consecutive patients with documented typical (CTI dependent) atrial flutter undergoing CTI ablation according to the inclusion and exclusion criteria.

Study groups and randomization Group 1 - MVG: maximum voltage guided stepwise CTI ablation (stepwise voltage guided approach (SVG)).

This cohort will be compared to Group 2 - control: patients undergoing conventional linear CTI ablation.

Primary endpoint Cumulative ablation duration (total radiofrequency energy delivery time) in seconds that is needed to achieve sustained complete BCB (acute procedural efficacy).

Secondary endpoints see below.

Follow-up Three months after ablation a diagnostic electrophysiologic (EP) study is performed to evaluate persistence of CTI block. In the case of recurrent conduction the indication is given for re-ablation.

Six and 12 months after ablation patients are invited for a clinical investigation and a 72 hours Holter monitoring is performed.

Sample size

  • Primary Endpoint: procedural efficacy - ablation duration (total radiofrequency energy delivery time)

    • Primary hypothesis: MVG ablation strategy reduces the duration of RF energy application (time to CTI block) by at least 35% compared to conventional linear approach For result analysis it is planned to use a non-parametric Wilcoxon-Mann-Whitney test since the primary endpoint is not normally distributed
    • Prospective randomized trial, PROBE design
    • Group 1: treatment with MVG ablation (stepwise approach)
    • Group 2: treatment with conventional linear ablation approach
    • Sample size estimation Based on the results from Deutsch et al., Medicine 2017
  • Conventional pull back/ fluoroscopy as low as reasonable achievable (ALARA): 726±454 sec.
  • MVG/minimal fluoroscopy: 473±317 sec.

Compare two means two side, parametric test:

  • 76 patients (2 groups with 38 pts per group)
  • power 80%, α=0.05, ratio 1:1 Due to planned use of a non-parametric test 15% are added to the sample size resulting from the parametric test estimation
  • Sample size: 88 patients (44 each group) plus 20% expected dropout rate: => overall sample size 106 patients (53 patients each group)

Statistics Data will be collected in a hospital-internal Excel file. The data will be initially analyzed descriptively, including frequencies and percentages for categorical data, and mean, standard deviation, median and quartiles for continuous data.

To evaluate the primary endpoint we plan to use a non-parametric Wilcoxon-Mann-Whitney test for comparison of a population not normally distributed, due to non-normality reported in former studies. We define p \< 0.05 as statistically significant.

Randomization Randomization will occur once patient has been determined eligible for the study, he/she has received the appropriate and mandatory information about the study and the informed consent form has been signed. Patients will be randomly assigned with ratio 1:1 to one of two treatment arms.

The randomization list will be generated using the Wei's Urn Design method as implemented in the R package randomizeR.

Ethical consideration The study has been approved by the responsible ethics committee. In all respects, the clinical trial will be conducted in full conformance with principles of the "Declaration of Helsinki and, Good Clinical Practice (GCP).

All responsible physicians will provide a valid GCP training. All participating patients have the medical indication for curative CTI ablation according to the current medical guidelines.

Informed consent Written informed consent is required from all subjects prior to their participation in the study.

Patients insurance The study does not evaluate the performance of a medical product. All hardware and software including the catheter and EAM system are commercially available and used strictly according to their Conformité Européenne (CE) marking and specification. There is no increased radiation exposure due to the study. Despite the very low risks potentially associated to the study, a patients insurance policy will be taken out with an insurance company.

Investigator sponsored research The ZERO MAGIC trial is conducted as an investigator sponsored research (ISR) project in cooperation with Boston Scientific. The contract between the company Boston Scientific and the Klinikum Fuerth has been reviewed and approved in detail by the department for compliance from the Klinikum Fuerth.

Data management and data security The screening and informed consent process according to the inclusion and exclusion criteria will be performed by the PI and co-investigators. All participating investigators are instructed in the study protocol and provide a valid GCP training.

All demographic and procedural data will be listed in a password-protected hospital-internal Excel database according to the modified principles of the Declaration of Helsinki and Good clinical Practice. Access to the data base is restricted to the PI and co-investigators. In the data base, a cryptographic "hash" algorithm will be used for pseudonymization of patients' identifying data such as name and birth date. The code book for re-identification is password protected and the access strictly limited to Dr. Bastian, Dr. Vitali-Serdoz as PI and first co-investigator.

Data will be kept in the database for a minimum of ten years.

03

Conditions studied

  • Catheter Ablation
  • Atrial Flutter Typical
  • Radiation Exposure

Browse trials for

Keywords

  • atrial flutter typical
  • catheter ablation
  • electroanatomic mapping
04

Who can participate

Ages eligible
18 Years and older
Sexes eligible
All
Accepts healthy volunteers
No

Go through the criteria one by one — yes, no or not sure — and take the list to your doctor or the study team. Kept in this browser only.

Inclusion criteria

  • Typical (CTI dependent) atrial flutter documented in a standard 12 lead surface
  • Given class I indication for curative CTI ablation according to the current guidelines
  • Over 18 years old
  • Given

Exclusion criteria

Exclusion Criteria:

  • Any for CTI ablation
  • Previous CTI ablation
  • BCB as procedural endpoint not assessable
  • CTI ablation conducted in association with further ablation procedures
  • Patients with CIED (e.g. pacemaker, ICD)
  • Tricuspid valve replacement
  • Right atrial thrombus
  • Pregnant or breastfeeding women
  • Abuse of drugs or alcohol
  • Age \< 18 years
  • Incompliance to the treatment, e.g. necessary anticoagulation
  • Expected survival less than one year
  • Inability to understand the nature and rationale of the study
  • Inability to take part in the follow up
Terms in these criteria, in plain language(3)

Underlined terms in the criteria open these too. Explained by clinicaltrials.gg, not part of the registry record. The study team decides who can take part.

ECG (electrocardiogram)

A recording of the heart’s electrical activity, taken with stickers on the chest, arms and legs. It takes a few minutes and does not hurt.

Informed consent

Before you join, the study team explains what taking part involves — its purpose, what happens, the risks and possible benefits — and answers your questions, so you can decide freely. Consent is usually recorded on a form (the informed consent form, ICF) signed by you or, where the law allows, by someone legally authorized to decide for you.

You can keep asking questions during the study, you are told of new information that matters, and you can choose to leave at any time.

Contraindication

A reason a treatment, test or procedure should not be given to a particular person, such as an allergy, another illness or a medicine they take.

05

Study design

Phase
Not applicable
Primary purpose
Treatment
Allocation
Randomized
Intervention model
Parallel assignment
Masking
Double (Participant, Outcomes assessor)
Enrollment
106 participants (estimated)

Study arms

  • Active comparator
    Group 1: MVG ablation

    Group 1 - MVG: high-resolution mapping and maximum voltage guided stepwise CTI ablation (stepwise voltage guided approach (SVG)).

    Procedure: HR electroanatomic mapping and MVG catheter ablation

  • Active comparator
    Group 2 - control: linear ablation

    Group 2 - control: conventional bipolar mapping and conventional linear CTI ablation.

    Procedure: Conventional bipolar mapping and linear catheter ablation

Interventions

  • ProcedureHR electroanatomic mapping and MVG catheter ablation

    High resolution CTI mapping using the mini-electrodes at the 8 mm catheter tip followed by voltage guided ablation

  • ProcedureConventional bipolar mapping and linear catheter ablation

    Bipolar mapping and conventional anatomic linear catheter ablation

06

What researchers measure

Primary outcomes

  1. Cumulative ablation duration

    Cumulative ablation duration (total radiofrequency (RF) energy delivery time) in seconds that is needed to achieve sustained complete CTI block (acute procedural efficacy)

    Time frame: during procedure

Secondary outcomes

  1. Number of RF ablation points, which are necessary to achieve CTI block

    Total number of RF ablation points with minimal local energy-delivery of 20 seconds, which are necessary to achieve CTI block

    Time frame: during procedure

  2. Total amount of RF energy delivery for CTI block

    Total amount of RF energy delivery for sustained CTI block (in kilo Joules)

    Time frame: during procedure

  3. Rate of procedure related adverse events

    Safety: The rate of all procedure related adverse events will be documented and analyzed

    Time frame: during procedure

  4. Fluoroscopy time

    The cumulative fluoroscopy duration (in minutes)

    Time frame: during procedure

  5. Fluoroscopy exposure

    Effective dose (ED in μSv)

    Time frame: during procedure

  6. Number of participants with persistence of CTI block

    Number of patients with persistent bidirectional CTI block in electrophysiologic re-evaluation after 3 months.

    Time frame: 3 months follow-up

07

Study locations

1 of 1 sites recruiting
08

References and documents

Individual participant data

Plan to share: No

No publications or documents are linked to this record.

09

Timeline

Tracking since Sep 25, 2026
ElapsedEstimatedEstimated, not yet reachedSimilar studies: half by the dot; the band is the middle halfHalf of similar studies reached it by the dot; the band is the middle half, from a quarter to three quarters

Started Nov 2020 (actual). Primary completion is estimated for Aug 2026, 69 months after the start.

Of 55 interventional studies with no phase under Atrial Flutter, half reached primary completion within 31 months of starting (the median), counting those still running; a quarter within 14 and three quarters within 63. This study's planned 69 months is above that.

How these figures are worked out, and which studies are left out of them.

Registered
Dec 14, 2020
First posted
Dec 21, 2020
StartActual
Nov 30, 2020
Primary completionEst.
Aug 31, 2026
CompletionEst.
Aug 31, 2027
Last update
Jun 15, 2026
What these dates mean
Start.
When the first participant enrolled; while estimated, when the study expects to open to recruitment.
Primary completion.
When the last participant was examined or treated to collect data for the study's main question, its primary outcome. A study that stopped early gives the date its data collection stopped.
Completion.
When the last participant's last visit took place, for every outcome, secondary ones and side effects included: the end of the study. Often later than primary completion, sometimes the same day.
Actual and Est.
Actual means the registry says the date has happened. Est. (estimated) is a date the sponsor plans or expects. It can still move, and the sponsor is expected to change it to actual once it has passed.
No changes since tracking began. The registry record was last updated on Jun 15, 2026, before this site started recording changes on Sep 25, 2026. Its history is on ClinicalTrials.gov ↗
10

Registry details

Key details

Study ID
NCT04678258
Lead sponsor
Klinikum-Fuerth
Collaborators
Boston Scientific Corporation, University of Trieste
Responsible party
Sponsor
First posted
Dec 21, 2020
Start date
Nov 30, 2020
Primary completion
Aug 31, 2026 (estimated)
Completion
Aug 31, 2027 (estimated)
Last update
Jun 15, 2026

Study contacts

Dirk Bastian, MD
Contact
dirk.bastian@klinikum-fuerth.de
7580 1101 ext. +49 911
Laura Vitali-Serdoz, MD
Contact
laura.vitali-serdoz@klinikum-fuerth.de
7580 1101 ext. +49 911
Dirk Bastian, MD
principal investigator · Klinikum-Fuerth

Oversight

Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No
View the source record on ClinicalTrials.gov ↗

Interested in this study?

Eligibility is decided by the study team. Share this record with your doctor or contact the team directly.

Contact study team

Follow this study

Get an email when the registry record changes — status, dates, results — or when someone posts here.

Sign in to follow

Discussion

Questions and observations about this study, from anyone following it. Not medical advice, and not a channel to the study team — their contact details are on the registry record.

Sign in to join the discussion. Reading takes no account; posting does. You choose a display name, and a pseudonym is the default.

Nothing here yet. If you are running this trial, taking part in it, or weighing whether to, this is the place to say so.

Start the discussion