This study is aiming to evaluate the periodontal status of the abutment teeth in Polyetheretherketone ( PEEK ) framework partial dentures compared with cobalt-chromium ones in mandibular kennedy class I edentulous cases aiming to preserve the optimum periodontal health of the abutment teeth .
Cairo University is the lead sponsor of 4,780 studies on the registry; 1,427 are open to participants now.
Of its 36 completed or terminated interventional studies of FDA-regulated products, 5 (14%) have results posted.
Counted across the registry records on this site, refreshed daily.
Exclusion Criteria:
It's the gold standard biocompatible metal alloy used in thin sections, provide high strength and stiffness ,conduct heat and cold for a more natural experience, and is resistant to corrosion but their disadvantages include esthetic issues with metal display, oral galvanism, adverse tissue reactions,and osteolysis of abutment teeth.
Device: cobalt-chromium framework partial dentures
It's a promising polymer-based framework has recently been introduced which is made of polyetheretherketone polymer frame combined with acrylic resin denture teeth and a conventional acrylic resin denture base.
Device: PEEK framework partial dentures
It's a biocompatible metal alloy used in thin sections and are less bulky, provide high strength and stiffness ,conduct heat and cold for a more natural experience, enable designs that minimize the covering of the gingival margins, allow for a stable denture base, and is resistant to corrosion. Disadvantages include hypersensitivity, esthetic issues with metal display, oral galvanism, adverse tissue reactions, osteolysis of abutment teeth, and biofilm production .
It's a promising polymer-based framework material has recently been introduced which is made of polyetheretherketone polymer frame combined with acrylic resin denture teeth and a conventional acrylic resin denture base.
Periodontal status
periodontal status of the abutment teeth assessed by a periodontal chart .
Time frame: Change in periodontal status will be assessed at base line , after one month and after 3 months .
Plan to share: Undecided
This study is status unknown, as verified in Dec 2018. You cannot join it, but the record below documents what was studied.
Get an email when the registry record changes — status, dates, results — or when someone posts here.
Sign in to followQuestions and observations about this study, from anyone following it. Not medical advice, and not a channel to the study team — their contact details are on the registry record.
Sign in to join the discussion. Reading takes no account; posting does. You choose a display name, and a pseudonym is the default.
Nothing here yet. If you are running this trial, taking part in it, or weighing whether to, this is the place to say so.
Cairo University