Blood-pressure Measuring in Patients Carrying a Left Ventricular Assist Device

An interventional study of Blood-pressure measuring (Nellcor™ Adult SpO2 Sensor) in Left Ventricular Assist Device, sponsored by Insel Gruppe AG, University Hospital Bern. Completed at 1 site in Switzerland. Open to participants aged 18 Years and older. Per ClinicalTrials.gov, last updated 2021-11-23.

Sponsored by Insel Gruppe AG, University Hospital Bern · Not applicable, Interventional, and Diagnostic

Phase
Not applicable
Study type
Interventional
Enrollment
30
Allocation
Not applicable
Ages
18 Years and older
Sex
All
01

Study summary

To prove the novel device is able to reliably detect pulsatility in patients with CF-VADs and to analyze whether pre-programmed intrinsic pulsatility of the 3rd generation CF-VADs can also be picked up. The study is not designed to measure blood pressure.

Should this pilot study be successful in detecting enough pulsatility a follow-up study would then try to transfer the results into blood-pressure values with the help of comparators in order to identify an easier and more reliable method to measure BP in CF-VAD patients. .

Read the detailed description

The number of patients supported by left ventricular assist device (LVAD) is increasing as durable mechanical support has become widely available for end stage heart failure as destination therapy and as bridge to transplantation. The accurate measurement of blood pressure (BP) as well as the recognition and management of hypertension in patients with LVADs is an essential component of optimal clinical care. Hypertension is an established long-term risk factor for cardiovascular disease. The measurement of BP and the management of hypertension in patients with CF-VADs can present unique challenges. Patients with LVADs often do not have a palpable pulse, and therefore traditional BP measurement by auscultation or automated cuff is less reliable. Conventional occlusive BP measurement is able to to pick up signals in approximately 50% of cases due to coincidental phases of pulsatility. The arterial line is the gold standard, but is an invasive procedure and not practical for routine outpatient use.

Although efforts are underway to identify an easier and more reliable method to measure ambulatory BP in these patients not one has been able to match the quality of an invasive arterial line.

02

Conditions studied

  • Left Ventricular Assist Device

Keywords

  • Blood pressure measuring
03

Who can participate

Ages eligible
18 Years and older
Sexes eligible
All
Accepts healthy volunteers
No

Inclusion criteria

  • Patients carrying one of the two third generation CF-VADS (Heartware HVAD, Heartmate 3)
  • Patients >18y
  • Good understanding of written and oral German
  • Signed informed consent
  • Scheduled for routine outpatient appointment.

Exclusion criteria

Exclusion Criteria:

  • In the population of the outpatient clinic's CV-LVAD patients no known exclusion criteria exists
04

Study design

Phase
Not applicable
Primary purpose
Diagnostic
Allocation
Not applicable
Intervention model
Single group
Masking
None (open label)
Enrollment
30 participants (actual)

Study arms

  • Other
    All patients

    Nellcor™ Adult SpO2 Sensor

    Device: Blood-pressure measuring (Nellcor™ Adult SpO2 Sensor)

Interventions

  • DeviceBlood-pressure measuring (Nellcor™ Adult SpO2 Sensor)

    Data will be acquired for 10 minutes with a reusable off the shelf adult SpO2 sensor. The Nellcor™ Adult SpO2 Sensor, model DS-100A, is indicated for use when continuous noninvasive arterial oxygen saturation and pulse rate monitoring are required for patients weighing greater than 40 kg.

    Also known as: Nellcor™ Adult SpO2 Sensor

05

What researchers measure

Primary outcomes

  1. RR (Riva Rocci, indirect blood pressure measurement) in LVAD

    Detect pulsatility in CF-VAD (Continuous flow- ventricular assist device) patients sufficient to calculate comprehensible blood-pressure values in future follow-up studies

    Time frame: 10 min blood measuring

06

Study locations

1 site
  • University Hospital Bern
    Bern, 3010, Switzerland
07

References and documents

Publications

  • Saeed O, Jermyn R, Kargoli F, Madan S, Mannem S, Gunda S, Nucci C, Farooqui S, Hassan S, Mclarty A, Bloom M, Zolty R, Shin J, D'Alessandro D, Goldstein DJ, Patel SR. Blood pressure and adverse events during continuous flow left ventricular assist device support. Circ Heart Fail. 2015 May;8(3):551-6. doi: 10.1161/CIRCHEARTFAILURE.114.002000. Epub 2015 Apr 13. PubMed 25870369 ↗
  • Lampert BC, Eckert C, Weaver S, Scanlon A, Lockard K, Allen C, Kunz N, Bermudez C, Bhama JK, Shullo MA, Kormos RL, Dew MA, Teuteberg JJ. Blood pressure control in continuous flow left ventricular assist devices: efficacy and impact on adverse events. Ann Thorac Surg. 2014 Jan;97(1):139-46. doi: 10.1016/j.athoracsur.2013.07.069. Epub 2013 Sep 25. PubMed 24075484 ↗
08

Registry details

Key details

Study ID
NCT03458988
Lead sponsor
Insel Gruppe AG, University Hospital Bern
Responsible party
Sponsor
First posted
Mar 8, 2018
Start date
Feb 27, 2018
Primary completion
Oct 31, 2020
Completion
Dec 31, 2020
Last update
Nov 23, 2021

Study contacts

David Reineke, MD
principal investigator · University Hospial Bern, Cardio Vascular Surgery

Oversight

Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No
View the source record on ClinicalTrials.gov ↗

Not currently enrolling

This study is completed, as verified in Nov 2021. You cannot join it, but the record below documents what was studied.

Follow this study

Get an email when the registry record changes — status, dates, results — or when someone posts here.

Sign in to follow

Discussion

Questions and observations about this study, from anyone following it. Not medical advice, and not a channel to the study team — their contact details are on the registry record.

Sign in to join the discussion. Reading takes no account; posting does. You choose a display name, and a pseudonym is the default.

Nothing here yet. If you are running this trial, taking part in it, or weighing whether to, this is the place to say so.

Start the discussion