An observational study in Hip Osteoarthritis, Hip Necrosis and Hip Dysplasia, sponsored by Embody Orthopaedic Limited. Active, not recruiting at 2 sites in United Kingdom. Open to participants aged 18 Years to 70 Years. Per ClinicalTrials.gov, last updated 2026-08-13.

Sponsored by Embody Orthopaedic Limited · Observational

Study type
Observational
Model
Case-only
Time perspective
Prospective
Enrollment
250
Ages
18 Years to 70 Years
Sex
All
01

Study summary

This is a prospective, non-randomized, consecutive series, multicentre, observational study to evaluate the clinical outcome of ceramic-on- ceramic hip resurfacing arthroplasty using the ceramic, non-porous, non-cemented H1 Hip Resurfacing Arthroplasty. It includes a safety study followed by an efficacy study. Patients will be followed up for 10-years postoperatively.

The primary aim is to confirm the safety of the H1 hip resurfacing prosthesis by demonstrating non-inferiority of the H1 device in terms of survivorship.

The secondary is to evaluate superiority of the ceramic-on-ceramic H1 hip resurfacing prosthesis compared to Metal-on-Metal (MoM) hip resurfacing in terms of absence of metal ion release.The primary end point is revision for any reason.

Read the detailed description

Investigation type: Premarket study to receive a CE marking, followed by post-marketing surveillance follow-up.

Investigation design: Multi-centre, prospective, non-randomized, observational study

Investigation objectives:

The primary objective is to confirm the safety and efficacy of the H1 hip resurfacing prosthesis by demonstrating non-inferiority of the cumulative percent success in subjects implanted with the H1 hip resurfacing compared to a literature reference rate of the Birmingham hip resurfacing (BHR).

The secondary objective is to demonstrate superiority of the ceramic-on-ceramic H1 hip resurfacing prosthesis with its metal-free articulation compared to MoM hip resurfacing in the absence of metal ion release. Additional goals are to demonstrate non-inferiority of the ceramic-on-ceramic H1 hip resurfacing prosthesis compared to hip resurfacing with regard to patient reported outcome measures, objective clinical and functional outcomes, and radiological assessment.

The primary endpoint is revision for any reason

Secondary endpoints:

  • Complication rate (adverse events and revisions)
  • Toxicology (blood metal ion measurements)
  • CT assessment (Implant migration)
  • Patient Reported Outcome Measures (PROMs)
  • Objective clinical and functional outcomes (Harris Hip Score, Gait Analysis)
  • Radiological assessment (implant orientation, osseointegration)

Background Information

Total Hip Arthroplasty (THA) is one of the most successful surgical interventions. Replacement of an arthritic hip joint provides significant pain relief and improvement of hip function and mobility. Patients, even elderly people, are more active, have a better quality of life, less comorbidities and a longer life expectancy. The World Health Organisation (WHO) has declared THA the second best intervention, only preceded by cataract surgery, regarding cost effectiveness and quality of outcome. In patients older than 70 years, the overall survivorship of THA is more than 90% at 10 years and the best clinical results are obtained for THA as a treatment for osteoarthritis (OA). In this patient population, THA can thus be considered a lifelong solution. However, both survivorship and clinical results are much worse in young and active people. The reasons for this worse outcome are multiple. First of all, younger people usually have a more active lifestyle regarding work and sports. Secondly, the hip disorders leading to THA in a younger patient population are more difficult to treat. Congenital hip dysplasia is frequently associated with gross hip deformities, as may be the case in secondary traumatic OA. Bone stock may be jeopardised in cases of avascular necrosis of the femoral head (AVN) and rheumatoid arthritis (RA). Thirdly, a faster bone metabolism may play a role, but this remains to be elucidated.

Modern hip resurfacing arthroplasty (HRA) was introduced to address the inferior survivorship and unsatisfactory clinical results with THA in young and active patients. The anatomical reconstruction of the joint has the potential to provide a better function and higher activity levels compared to THA. Hip resurfacings are inherently higher performing than total hip replacements because they preserve the flexibility of native femoral head and neck. Metal-on-Metal (MoM) hip resurfacings have been shown to be safe and effective in many patients. These patients have superior clinical function over patients with total hip replacements, with little or no wear at the bearing surface in comparison to hard on soft bearings. The two most serious complications following hip surgery are death and infection. Both of these are substantially rarer after hip resurfacing when compared to patients with a cemented total hip arthroplasty, which is often presented as the gold standard of hip replacement. However, patients with poorly positioned hip resurfacing implants, poorly designed implants and smaller sizes especially in females have reported progressive pain leading to early revision. This pain is commonly caused by one of two problems: either metal ion particles generated by excessive wear associated with adverse soft tissue reactions to metal debris or soft tissue impingement on the hard metal edges of the components. Despite these two problems, hip registries continue to show superior survivorship of hip resurfacing using a well-designed device in young and active males when compared to total hip arthroplasty.

Higher metal ion levels have been found in whole blood, serum and urine of patients with MoM hip arthroplasties (THA and HRA) compared to preoperative values, and to THA with other bearing surfaces (metal-on-polyethylene, ceramic-on-polyethylene, ceramic-on-ceramic). Although MoM hip arthroplasty has been shown to produce less volumetric wear compared to metal-on-polyethylene, the wear debris consists of more numerous, small, nanometre size particles, which are ingested by macrophages. Contrary to polyethylene, metal particles and ions are not chemically inert but may have directly toxic, biological effects and may elicit hypersensitivity reactions in addition to the macrophage-driven, innate, foreign-body immune responses to particulate debris of any material. Consequently, concerns have been raised about the physiological consequences of metal release from MoM hip prostheses into the peri- prosthetic tissue and systemic circulation.

By exchanging the metal material of the bearing with BIOLOX®delta ceramic, a better wearing and more inert material, the positive clinical performance aspects of MoM hip resurfacings are retained, while the main cause of early revision is removed. The anatomic shape of the contours of the devices may go some way to reducing the pain caused by soft tissue erosion, Thus, the H1 ceramic-on-ceramic hip resurfacing could be used for wider indications than the currently restricted group of large men. Patients with smaller head sizes, females and patients with metal sensitivity may all be candidates, enabling them the option to have a more conservative operation if appropriate.

The H1 hip resurfacing design is innovative both in its anatomical shape and in the bearing couple materials as there is currently no all-ceramic bearing hip resurfacing implant in clinical use. Ceramic-on-ceramic THA has a proven track record with excellent survivorship results in the arthroplasty registries as well as low complication rates and good functional results from large clinical series. The materials have been thoroughly tested regarding biocompatibility, biomechanical and tribological characteristics, and have been used in over one million clinical cases over the last 11 years, confirming safety of the material. However, a mono-block ceramic acetabular component without a metal shell such as the H1 hip has not yet been used clinically. The concept requires investigation before it can be CE marked and marketed in Europe.

The anatomical contoured edge of both the cup and the head reduces the incidence of psoas impingement. The iliopsoas tendon is stretched over the femoral head when the hip is extended. In the normal hip, the tendon runs over the front edge of the acetabulum, and femoral head, which it uses as a fulcrum giving some leverage advantage as the muscle contracts to lift the leg up when bringing the leg up into the bath or into a high car for instance. When the femoral head is resurfaced, the tendon has to rub over the hard edge of the resurfacing device. Until now, femoral resurfacing devices have had a symmetric rim, which tends to extend beyond the normal limits of a femoral head, particularly in female hips. This overhang can cause painful abrasion of the tendon. Most acetabular components are also symmetric in shape, unlike the natural acetabular rim contour, which has a recess where the tendon runs. The rim of the acetabular shell can also be a cause of tendon irritation.

BIOLOX®delta is a zirconia toughened alumina (ZTA). Along with alumina (Al) and zirconia (Zr), this material also contains traces of chromium (Cr), strontium (Sr) and very low amounts of yttrium (Y). This ceramic has an 11-year history of worldwide use in hip arthroplasty, with an excellent track record. Ceramic-on-ceramic bearings consist of the hardest material with the lowest wear rate of all bearing couples used in hip arthroplasty. The very low volume of inert ceramic nanoparticles and the absence of elevated Cobalt (Co) and Cr ion levels in the bloodstream virtually abolishes the risk of adverse local tissue reactions (ALTR), allergic reactions and systemic cobalt toxicity which can complicate some MoM Hip replacements. BIOLOX®delta contains very small amounts of Cr, but Cr release from the material remains below the detection limit in the blood. Strontium ions are found in the blood of control patients without any implant and remain at similar background level in patients with BIOLOX®delta ceramic implants, Yttrium ions are not detected.

BIOLOX®delta is a zirconia-toughened alumina ceramic with increased fracture strengths. The use of BIOLOX®delta has virtually eliminated the already low fracture risk of the older ceramic implants. The fracture risk in the arthroplasty registries and as assessed by the manufacturer CeramTec is now estimated at \< 0.001%.

Besides a significantly lower risk of mortality with hip resurfacing compared to conventional cemented total hip arthroplasty (THA), the use of BIOLOX®delta ceramic on ceramic bearings further reduces the risk of the most devastating complication associated with THA, i.e. periprosthetic infection . Because of a significant reduction in biofilm formation and adherence to ceramic surfaces (69%) compared to metal (92%) and highly cross-linked polyethylene (HXL PE) (100%), the risk of periprosthetic infection is significantly reduced, to \<0.5% at 10 years compared to >1% with polyethylene bearings including HXL PE.

The uncemented fixation of the H1 hip resurfacing is not novel. The porous ingrowth coating of plasma sprayed titanium and hydroxyapatite has been applied by a leading implant coating specialist (Medicoat AG, Mägenwil, Switzerland). Acetabular cups using these coatings are now standard products with more than 15 years of experience. Several metal-on-metal hip resurfacing designs for non-cemented use, have successfully been implanted in large series of patients. Ti ions may be released as part of the bone ingrowth process of the non-cemented hip of knee prosthesis, but Ti_ions from Titaniumdioxyde (TiO2) coatings or Titanium-aluminum-vanadium (TiAlV) hip or knee arthroplasty components are not associated with toxic, teratogenic or carcinogenic reactions.

02

Conditions studied

  • Hip Osteoarthritis
  • Hip Necrosis
  • Hip Dysplasia

Keywords

  • Hip Resurfacing Arthroplasty
  • Ceramic
  • Cementless
  • H1
03

In context

Osteoarthritis, Hip

641 studies on the registry are indexed under Osteoarthritis, Hip; 120 are open to participants now.

This study's planned enrollment of 250 is above the median of 135 across 158 observational studies indexed under Osteoarthritis, Hip.

Browse Osteoarthritis, Hip studies →

Lead sponsor

Embody Orthopaedic Limited is the lead sponsor of 2 studies on the registry; 1 is open to participants now.

Counted across the registry records on this site, refreshed daily.

04

Who can participate

Ages eligible
18 Years to 70 Years
Sexes eligible
All
Accepts healthy volunteers
No
Sampling method
Non-probability sample

Study population

Indications for use of the H1 HRA in this investigation will be patients with end-stage hip disease who are candidates for primary hip arthroplasty using either a metal-on-metal hip resurfacing or a ceramic-on- ceramic THR. Typically they will be younger (\<70 years) and active males and females with end-stage hip osteoarthritis, avascular necrosis of the femoral head, post-traumatic osteoarthritis or developmental dysplasia of the hip (DDH).

Go through the criteria one by one — yes, no or not sure — and take the list to your doctor or the study team. Kept in this browser only.

Inclusion criteria

  • Patient requires primary hip arthroplasty due to degenerative joint disease (primary osteoarthritis, posttraumatic osteoarthritis, avascular necrosis, developmental hip dysplasia)
  • Patient is eligible for hip resurfacing arthroplasty: i.e. has sufficient bone stock at the level of the femoral head (\<1/3 necrosis of the head) and neck (not osteopenic/porotic, see exclusion criteria)
  • Patient is between 18 and 70 years old
  • Patient willing to comply with study requirements
  • Patient is legally entitled and able to consent, agrees to consent to and to follow the study visit schedule (as defined in the study protocol and form), by signing the informed consent form approved by the Ethics Committee.
  • Patient plans to be available through ten (10) years postoperative follow-up
  • Patient is able to understand the native language of the country of the trial centre

Exclusion criteria

Exclusion Criteria:

  • Patient has a greater than 40
  • Patient suffers from an active inflammatory joint disorder
  • Patient has an active infection or sepsis (treated or untreated)
  • Patient has insufficient bone stock at the hip (>1/3 necrosis of the femoral head) or in general as in severe osteopenia or osteoporosis (Tscore \< -2.5 as measured with BMD)
  • At the time of enrolment, patient has one or more of the following arthroplasties that have been
  • Implanted less than 6 months before the current hip arthroplasty:
  • Contralateral primary total hip arthroplasty or hip resurfacing arthroplasty
  • Ipsilateral or contralateral primary total knee or unicondylar knee arthroplasty
  • Patient takes medications which potentially affect the bone such as and antimitotic medications.
  • Patient has a condition that may interfere with the hip arthroplasty survival or outcome (i.e. Paget's or Charcot's disease, vascular insufficiency, muscular atrophy, uncontrolled diabetes, moderate to severe renal insufficiency or neuromuscular disease)
  • Patient has a known alcohol or drug abuse
  • Patient has an disorder
  • Patient has a malignant tumour, , or neoplastic disease
  • Patient has severe comorbidities or a limited
  • Patient lacks capacity to consent
  • Patient has an emotional or neurological condition that would pre-empt his/her ability or willingness to participate in the study
  • Patient is not willing or able to sign an form
  • Patient pregnant or breast feeding
  • Patient is not able or willing to come to follow-up visits
  • In addition, the following exclusion criteria are applied to the 20 patients (Cohort 1 and Cohort 1.1) in the safety study in whom metal ion measurements will be performed, since those conditions may be associated with elevated metal ion levels and could complicate the interpretation of the metal ion results:
  • Patients who already received another joint replacement, hip, knee, shoulder, ankle.
  • Workers in the paint, diamond, leather or other industries producing Co or Cr dust.
  • Patients taking medication, vitamins or food supplements containing Co or Cr and not able or willing to discontinue those.
Terms in these criteria, in plain language(6)

Underlined terms in the criteria open these too. Explained by clinicaltrials.gg, not part of the registry record. The study team decides who can take part.

Informed consent

Before you join, the study team explains what taking part involves — its purpose, what happens, the risks and possible benefits — and answers your questions, so you can decide freely. Consent is usually recorded on a form (the informed consent form, ICF) signed by you or, where the law allows, by someone legally authorised to decide for you.

You can keep asking questions during the study, you are told of new information that matters, and you can choose to leave at any time.

BMI (body mass index)

Weight in kilograms divided by height in metres squared. Example: 70 kg and 1.75 m gives 70 ÷ (1.75 × 1.75) ≈ 22.9.

What counts as overweight or obesity differs between countries (some use lower cut-offs), so go by the range the study states.

Corticosteroids (steroids)

Anti-inflammatory medicines such as prednisone, prednisolone and dexamethasone — not the anabolic steroids used for muscle.

Studies differ in what they allow: check which steroid medicines, routes (tablets, injections, creams, inhalers, eye drops) and doses this study accepts.

Immunosuppression

A weakened immune system. It can come from an illness, such as HIV or some blood cancers, or from medicines that turn the immune system down, for example after an organ transplant or for an autoimmune disease; steroids at higher doses count.

Read whether the line is about a condition or about medicines, and which medicines and doses it means.

Metastases

Cancer that has spread from where it began to other parts of the body. “Metastatic” cancer is cancer that has spread this way.

Life expectancy

The study doctor’s estimate of how long someone is likely to live. Criteria use it so that people can stay in the study long enough for it to answer its question.

05

Study design

Observational model
Case-only
Time perspective
Prospective
Enrollment
250 participants (estimated)
Patient registry
No
Biospecimen retention
Samples without dna

Groups and cohorts

  • Cohort 1 - Safety

    Cohort 1 will consist of the first 20 participants recruited into the study for H1 Hip Resurfacing Arthroplasty. These patients will receive additional CT scans preoperatively and then post-operatively at these time points: immediately postoperatively (2days), at 6 weeks, 3 months, 6 months, 1 year and 2 years. They will have metal-ion measurements for safety analysis. Blood samples will be taken preoperatively and postoperatively at 3 months, 6 months, 1 year and 2 years. A safety analysis of Cohort 1 will be performed at the 6 week, 3 month and 6 month post-operative stage by independent assessors. Yearly clinical evaluations will be performed until 10 years, and radiographs at 3,5,10 years. If the investigation supports the safety of the implant, the study will proceed with recruitment into Cohort 2.

    Device: H1 Hip Resurfacing Arthroplasty

  • Cohort 2 - Efficacy

    Cohort 2 will consist of the remaining target size population of 230 patients for H1 Hip Resurfacing Arthroplasty. They will undergo the same intervention as previously described for Cohort 1, but will not undergo metal-ion testing and reduced frequency CT-scans.

    Device: H1 Hip Resurfacing Arthroplasty

Interventions

  • DeviceH1 Hip Resurfacing Arthroplasty

    A non-porous non-cemented ceramic-on-ceramic hip resurfacing arthroplasty device

06

What researchers measure

Primary outcomes

  1. Oxford Hip Score

    Hip Specific Patient Reported Outcome Measure (PROM)

    Time frame: 10 years

  2. EQ-5D Health-Related Quality of Life Questionnaire

    Generic Patient Reported Outcome Measure (PROM)

    Time frame: 10 years

Secondary outcomes

  1. Complication Rate

    Adverse Events and revisions

    Time frame: 10 years

  2. Clinical objective outcome measures

    Harris Hip Score

    Time frame: 10 years

  3. Acetabular Implant orientation

    Evaluation of AP and Lateral Hip Radiographs, measured in degrees

    Time frame: 10 years

  4. Femoral Implant orientation

    Evaluation of AP and Lateral Hip Radiographs, measured in degrees

    Time frame: 10 years

  5. Low-dose CT

    CT to evaluate component migration and bone ingrowth (Safety study - Cohort 1 - 20 patients)

    Time frame: Up till 2 years

  6. Metal ion measurements

    Concentration of metal ions in patient's blood (Safety study - Cohort 1 - 20 patients)

    Time frame: Up till 2 years

07

Study locations

2 sites
08

References and documents

Individual participant data

Plan to share: No

No publications or documents are linked to this record.

09

Timeline

Tracking since Sep 25, 2026
ElapsedEstimatedEstimated, not yet reachedSimilar studies: half by the dot; the band is the middle halfHalf of similar studies reached it by the dot; the band is the middle half, from a quarter to three quarters

Started Sep 2017 (actual). Primary completion is estimated for Mar 2032, 173 months after the start.

Of 81 observational studies under Osteoarthritis, Hip, half reached primary completion within 53 months of starting (the median), counting those still running; a quarter within 13 and three quarters within 113. This study's planned 173 months is above that.

How these figures are worked out, and which studies are left out of them.

Registered
Oct 15, 2017
First posted
Oct 31, 2017
StartActual
Sep 26, 2017
Primary completionEst.
Mar 17, 2032
CompletionEst.
Mar 25, 2033
Last update
Aug 13, 2026
What these dates mean
Start.
When the first participant enrolled; while estimated, when the study expects to open to recruitment.
Primary completion.
When the last participant was examined or treated to collect data for the study's main question, its primary outcome. A study that stopped early gives the date its data collection stopped.
Completion.
When the last participant's last visit took place, for every outcome, secondary ones and side effects included: the end of the study. Often later than primary completion, sometimes the same day.
Actual and Est.
Actual means the registry says the date has happened. Est. (estimated) is a date the sponsor plans or expects. It can still move, and the sponsor is expected to change it to actual once it has passed.
No changes since tracking began. The registry record was last updated on Aug 13, 2026, before this site started recording changes on Sep 25, 2026. Its history is on ClinicalTrials.gov ↗
10

Registry details

Key details

Study ID
NCT03326804
Lead sponsor
Embody Orthopaedic Limited
Responsible party
Sponsor
First posted
Oct 31, 2017
Start date
Sep 26, 2017
Primary completion
Mar 17, 2032 (estimated)
Completion
Mar 25, 2033 (estimated)
Last update
Aug 13, 2026

Study contacts

Justin P Cobb, FRCS
principal investigator · Imperial College London

Oversight

Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No
View the source record on ClinicalTrials.gov ↗

Not currently enrolling

This study is active, not recruiting, as verified in Aug 2026. You cannot join it, but the record below documents what was studied.

Follow this study

Get an email when the registry record changes — status, dates, results — or when someone posts here.

Sign in to follow

Discussion

Questions and observations about this study, from anyone following it. Not medical advice, and not a channel to the study team — their contact details are on the registry record.

Sign in to join the discussion. Reading takes no account; posting does. You choose a display name, and a pseudonym is the default.

Nothing here yet. If you are running this trial, taking part in it, or weighing whether to, this is the place to say so.

Start the discussion