Accuracy of Commercially Available Heart Rate Monitors II

An interventional study of Fit Bit Blaze Heart Rate Monitoring Device and Garmin Forerunner 235 Heart Rate Monitoring Device in Healthy, sponsored by The Cleveland Clinic. Completed. Open to participants aged 18 Years and older, including healthy volunteers. Per ClinicalTrials.gov, last updated 2017-07-02.

Sponsored by The Cleveland Clinic · Not applicable, Interventional, and Screening

Phase
Not applicable
Study type
Interventional
Enrollment
50
Allocation
Non-randomized
Ages
18 Years and older
Sex
All
01

Study summary

In 2015, over 85 million fitness wearables were sold worldwide and the market is projected to expand to 110 million units sold in 2017. Of all wearable technology, fitness devices that track heart rate are predicted to be the most popular. At the elite level, commercial heart rate monitors are being used by athletes like LeBron James, Blake Griffin, and Matthew Dellavedova to monitor and alter their behaviors for peak athletic performance. Millions of ordinary consumers purchase fitness trackers that include heart rate monitors in order to help them to maintain their health and wellness. As popularity of these fitness devices grows, assessment of the accuracy of heart rate measurements becomes increasingly important.

Read the detailed description

In a previous trial, investigators compared the accuracy of four devices (Apple Watch, Fitbit Charge HR, Mio Fuse, Basis Peak) worn by subjects while performing a graded exercise program on a treadmill. Investigators discovered that the Apple Watch and Mio Fuse had a correlation coefficient (rc) of .91, Fitbit Charge HR had an rc of .84, and Basis Peak had an rc of .83. That study has been submitted for publication.

Reviewers of the first study raised an important question: how do commercial optical heart rate monitors perform when measuring heart rate during other popular forms of exercise? This study addresses that question.

Objective:

The objective of this study is to evaluate the accuracy of four heart rate monitors when used during three different exercises: treadmill, stationary bicycle, elliptical trainer.

02

Conditions studied

  • Healthy

Keywords

  • commercial heart monitors
  • accuracy
  • EKG
  • varying degrees of exertion
03

In context

Lead sponsor

The Cleveland Clinic is the lead sponsor of 818 studies on the registry; 118 are open to participants now.

Of its 89 completed or terminated interventional studies of FDA-regulated products, 72 (81%) have results posted.

Counted across the registry records on this site, refreshed daily.

04

Who can participate

Ages eligible
18 Years and older
Sexes eligible
All
Accepts healthy volunteers
Yes

Inclusion criteria

  • Age > 18 years
  • Able and willing to exercise for a total of fifteen minutes

Exclusion criteria

Exclusion Criteria:

  • Health issues that preclude or contraindicate walking and/or jogging, including cardiovascular, orthopedic, pulmonary and other conditions
  • Presence of a cardiac pacemaker
  • Known cardiovascular disease
  • Known heart rhythm disorders
  • Use of Beta-blockers or antiarrhythmic medications
  • Tattoos around the wrist or forearm area
05

Study design

Phase
Not applicable
Primary purpose
Screening
Allocation
Non-randomized
Intervention model
Factorial assignment
Masking
None (open label)
Enrollment
50 participants (actual)

Study arms

  • Active comparator
    Fit Bit Blaze

    Fit Bit Blaze Heart Rate Monitoring Device

    Device: Fit Bit Blaze Heart Rate Monitoring Device

  • Active comparator
    Garmin Forerunner 235

    Garmin Forerunner 235 Heart Rate Monitoring Device

    Device: Garmin Forerunner 235 Heart Rate Monitoring Device

  • Active comparator
    Tom Tom Spark Cardio

    Tom Tom Spark Cardio Heart Rate Monitoring Device

    Device: Tom Tom Spark Cardio Heart Rate Monitoring Device

  • Active comparator
    Apple Watch

    Apple Watch Heart Rate Monitoring Device

    Device: Apple Watch Heart Rate Monitoring Device

  • Active comparator
    Scosche Rhythm +

    Scosche Rhythm + Heart Rate Monitoring Device

    Device: Scosche Rhythm + Heart Rate Monitor

Interventions

  • DeviceFit Bit Blaze Heart Rate Monitoring Device
  • DeviceGarmin Forerunner 235 Heart Rate Monitoring Device
  • DeviceTom Tom Spark Cardio Heart Rate Monitoring Device
  • DeviceApple Watch Heart Rate Monitoring Device
  • DeviceScosche Rhythm + Heart Rate Monitor
06

What researchers measure

Primary outcomes

  1. Primary Outcome Measure: Heart Rate Monitor Accuracy Compared to ECG Expressed as Correlation Coefficient.

    The primary outcome measure is the accuracy of each heart rate monitor compared to ECG. This will be expressed by the correlation coefficient and will also be depicted by Bland-Altman plots.

    Time frame: 24 minutes

07

Results

Posted Jul 2, 2017

Participant flow

All subjects who met inclusion criteria and had no exclusions were enrolled. All subjects who were consented, participated and completed the study wearing a device on each wrist.

Participant flow — Overall Study
MilestoneFit Bit BlazeGarmin Forerunner 235Tom Tom Spark CardioApple Watch
Started25252525
Completed25252525
Not completed0000

Outcome measures

PrimaryPrimary Outcome Measure: Heart Rate Monitor Accuracy Compared to ECG Expressed as Correlation Coefficient.

The primary outcome measure is the accuracy of each heart rate monitor compared to ECG. This will be expressed by the correlation coefficient and will also be depicted by Bland-Altman plots.

Time frame:
24 minutes
Reported as:
Mean · Concordance Correlation Coefficient wECG
Primary Outcome Measure: Heart Rate Monitor Accuracy Compared to ECG Expressed as Correlation Coefficient.
Concordance Correlation Coefficient wECGFit Bit BlazeGarmin Forerunner 235Tom Tom Spark CardioApple Watch
Primary Outcome Measure: Heart Rate Monitor Accuracy Compared to ECG Expressed as Correlation Coefficient..67 (.615 to .719).81 (.776 to .843).83 (.799 to .860).92 (.903 to .934)

Adverse events

Collected over 24 minutes. Non-serious events are listed at a 0% frequency threshold.

Adverse event summary by group
GroupDeathsSeriousOther
Fit Bit Blaze0/25 (0%)0/25 (0%)0/25 (0%)
Garmin Forerunner 2350/25 (0%)0/25 (0%)0/25 (0%)
Tom Tom Spark Cardio0/25 (0%)0/25 (0%)0/25 (0%)
Apple Watch0/25 (0%)0/25 (0%)0/25 (0%)

Baseline characteristics

Age, Categorical
Age, Categorical(Heart Rate)Fit Bit BlazeGarmin Forerunner 235Tom Tom Spark CardioApple WatchTotal
<=18 years00000
Between 18 and 65 years25252525100
>=65 years00000
Sex: Female, Male
Sex: Female, Male(Heart Rate)Fit Bit BlazeGarmin Forerunner 235Tom Tom Spark CardioApple WatchTotal
Female1412151354
Male1113101246
Race and Ethnicity Not Collected
Race and Ethnicity Not Collected(Participants)Fit Bit BlazeGarmin Forerunner 235Tom Tom Spark CardioApple WatchTotal
Count of participants————0
08

Study locations

No study locations are listed for this record.

09

References and documents

Individual participant data

Plan to share: Undecided

No publications or documents are linked to this record.

10

Updates

Tracking since Sep 25, 2026
No changes since tracking began. The registry record was last updated on Jul 2, 2017, before this site started recording changes on Sep 25, 2026. Its history is on ClinicalTrials.gov ↗
11

Registry details

Key details

Study ID
NCT02818244
Lead sponsor
The Cleveland Clinic
Responsible party
Marc Gillinov, MD (Principal Investigator, The Cleveland Clinic) — Principal investigator
First posted
Jun 29, 2016
Start date
Jun 2016
Primary completion
Oct 2016
Completion
Oct 2016
Results posted
Jul 2, 2017
Last update
Jul 2, 2017

Study contacts

Marc Gillinov, MD
principal investigator · The Cleveland Clinic

Oversight

Data monitoring committee
No
View the source record on ClinicalTrials.gov ↗

Not currently enrolling

This study is completed, as verified in Jun 2017. You cannot join it, but the record below documents what was studied.

Follow this study

Get an email when the registry record changes — status, dates, results — or when someone posts here.

Sign in to follow

Discussion

Questions and observations about this study, from anyone following it. Not medical advice, and not a channel to the study team — their contact details are on the registry record.

Sign in to join the discussion. Reading takes no account; posting does. You choose a display name, and a pseudonym is the default.

Nothing here yet. If you are running this trial, taking part in it, or weighing whether to, this is the place to say so.

Start the discussion