Pulse transit time (PuTT) - the time between R wave on ECG and initiation of upstroke in the peripheral arterial waveform - described in the previous studies as value that reflects changes in both blood pressure and blood volume. The investigators are assuming that PuTT changes reflect the dynamic of systolic blood pressure but not cardiac output fluctuations.
Background Pulse transit time (PuTT) - the time between R wave on ECG and initiation of upstroke in the peripheral arterial waveform - described in the previous studies as value that reflects changes in both blood pressure and blood volume. We are assuming that PuTT changes reflect the dynamic of systolic blood pressure but not cardiac output fluctuations.
Clinical trial objectives Investigate a link between PuTT (Pulse transit time) and changes in blood pressure and cardiac output measured by non-invasive cardiac output monitoring device (NICOM).
Endpoints PuTT Blood pressure: systolic, diastolic, mean Heart rate Cardiac output-Index Systemic vascular resistance-Index
Prospective nonrandomized clinical trial
Inclusion criteria Need for continuous invasive monitoring of blood pressure - according to the type of surgery the patient's health status Normal sinus rhythm
Exclusion criteria Pregnancy Cave to Nitroglycerine or Phenylephrine Chronic renal failure with creatinine level above 2 mg%
Safety assessment methods Monitoring of cardiac output is one of the most important elements of hemodynamic monitoring. In the past this monitoring was based mainly on the invasive and awkward methods causing usage only in exceptional cases. NICOM device allows accurate non-invasive monitoring of cardiac output During anesthesia patient care changes are made according to changes in vital indicators such as blood pressure, pulse, cardiac output. So during the study, anesthesia care can be affected by the indices obtained using a NICOM.
Data processing and analysis During the surgery the continuous monitoring of blood pressure by peripheral artery catheter and cardiac output by NICOM will be applied.
In case of hemodynamic changes the patient will be treated according to the standard care:
In case of decrease of systolic blood pressure below 80 mmHg (in the patients with history of arterial hypertension - below 90 mmHg) and HR is above 70 bpm the patient will be treated by repeated boluses of Phenylephrine 50-100 mcg until the systolic blood pressure will increase by at least 20%.
Intraoperative hypertension above 160 mmHg will be treated by repeated boluses of Nitroglycerine 100 mcg until the systolic blood pressure will decrease by at least 20%.
Hypovolemia will be treated by boluses of colloid solution - HAES 6% - at dose of 7 ml/kg of body mass during 15 min.
Study procedures
Cardiac output will be measured by NICOM just before and after each treatment of hemodynamic events that described above. Simultaneous records of ECG, arterial and plethysmographic waveforms will be made just before and after each event.
Systolic blood pressure and PuTT will be measured OFFLINE from the recorded waveforms.
Carmel Medical Center is the lead sponsor of 119 studies on the registry; 7 are open to participants now.
Counted across the registry records on this site, refreshed daily.
Patients undergoing various types elective surgery which require continous invasive monitoring of blod pressure
Go through the criteria one by one — yes, no or not sure — and take the list to your doctor or the study team. Kept in this browser only.
Exclusion Criteria:
Device: Non-invasive cardiac output monitoring
During the surgery the continuous monitoring of blood pressure by peripheral artery catheter and cardiac output by NICOM (non-invasive cardiac output monitoring) will be applied. In case of intraoperative hemodynamic changes (hypertension, hypotension) the patient will be treated according to the standard care by Phenylephrine, Nitroglycerine or Colloid fluid boluses. Cardiac output will be measured by NICOM just before and after each treatment of hemodynamic events that described above. Simultaneous records of ECG, arterial and plethysmographic waveforms will be made just before and after each event. Systolic blood pressure and PuTT will be measured OFFLINE from the recorded waveforms
Also known as: Cheetah Reliant, NICOM, Cheetah Medical
Pulse transit time (PuTT)
Simultaneous record of arterial line waveform and ECG will be made just before and 2 minute after giving one of treatments (Phenylephrine, Nitroglycerine or fluid bolus). PuTT will be measured offline from the record
Time frame: Two minutes after each intervention (giving Nitroglycerine, Phenylephrine or Fluid loading)
The record gives a start of Jan 2011, a primary completion of Nov 2013 and a completion of Nov 2013. It does not say whether these dates are actual or estimated.
How these figures are worked out, and which studies are left out of them.
This study is completed, as verified in Nov 2013. You cannot join it, but the record below documents what was studied.
Get an email when the registry record changes — status, dates, results — or when someone posts here.
Sign in to followQuestions and observations about this study, from anyone following it. Not medical advice, and not a channel to the study team — their contact details are on the registry record.
Sign in to join the discussion. Reading takes no account; posting does. You choose a display name, and a pseudonym is the default.
Nothing here yet. If you are running this trial, taking part in it, or weighing whether to, this is the place to say so.